  74HC139D Datasheet HTML 1Page - NXP Semiconductors 74HC139D Datasheet HTML 2Page - NXP Semiconductors 74HC139D Datasheet HTML 3Page - NXP Semiconductors 74HC139D Datasheet HTML 4Page - NXP Semiconductors 74HC139D Datasheet HTML 5Page - NXP Semiconductors 74HC139D Datasheet HTML 6Page - NXP Semiconductors 74HC139D Datasheet HTML 7Page - NXP Semiconductors  
Zoom Inzoom in Zoom Outzoom out
 2 / 7 page
background image
September 1993
2
Philips Semiconductors
Product specification
Dual 2-to-4 line decoder/demultiplexer
74HC/HCT139
FEATURES
• Demultiplexing capability
• Two independent 2-to-4 decoders
• Multifunction capability
• Active LOW mutually exclusive outputs
• Output capability: standard
• ICC category: MSI
GENERAL DESCRIPTION
The 74HC/HCT139 are high-speed Si-gate CMOS devices
and are pin compatible with low power Schottky TTL
(LSTTL). It is specified in compliance with JEDEC
standard no. 7A.
The 74HC/HCT139 are high-speed, dual 2-to-4 line
decoder/multiplexers. This device has two independent
decoders, each accepting two binary weighted inputs
(nA0 and nA1) and providing four mutually exclusive active
LOW outputs (nY0 to nY3). Each decoder has an active
LOW enable input (nE).
When nE is HIGH, every output is forced HIGH. The
enable can be used as the data input for a 1-to-4
demultiplexer application.
The “139” is identical to the HEF4556 of the HE4000B
family.
QUICK REFERENCE DATA
GND = 0 V; Tamb = 25 °C; tr = tf = 6 ns
Notes
1. CPD is used to determine the dynamic power dissipation (PD in µW):
PD = CPD × VCC2 × fi +∑ (CL × VCC2 × fo) where:
fi = input frequency in MHz
fo = output frequency in MHz
∑ (CL × VCC2 × fo) = sum of outputs
CL = output load capacitance in pF
VCC = supply voltage in V
2. For HC the condition is VI = GND to VCC
For HCT the condition is VI = GND to VCC − 1.5 V
APPLICATIONS
• Memory decoding or data-routing
• Code conversion
ORDERING INFORMATION
See
“74HC/HCT/HCU/HCMOS Logic Package Information”.
SYMBOL
PARAMETER
CONDITIONS
TYPICAL
UNIT
HC
HCT
tPHL/ tPLH
propagation delay
CL = 15 pF; VCC = 5 V
nAn to nYn
11
13
ns
nE3 to nYn
10
13
ns
CI
input capacitance
3.5
3.5
pF
CPD
power dissipation capacitance per multiplexer
notes 1 and 2
42
44
pF



Html Pages

1 2 3 4 5 6 7


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com