| 전자부품 데이터시트 검색엔진 |
|
L99DZ100GP 데이터시트(PDF) 94 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L99DZ100GP 데이터시트(HTML) 94 Page - STMicroelectronics |
|
94 / 197 page ![]() Application information L99DZ100G, L99DZ100GP 94/197 DS11546 Rev 5 low). If more or less clock pulses are counted within one frame the complete frame is ignored. This safety function is implemented to avoid an activation of the output stages by a wrong communication frame. Note: Due to this safety functionality a daisy chaining of SPI is not possible. Instead, a parallel operation of the SPI bus by controlling the CSN signal of the connected IC's is recommended. Serial Data Out (DO) The data output driver is activated by a logical low level at the CSN input and will go from high impedance to a low or high level depending on the global error flag (fault condition). The first rising edge of the CLK input after a high to low transition of the CSN Pin will transfer the content of the selected status register into the data out shift register. Each subsequent falling edge of the CLK will shift the next bit out. Serial Clock (CLK) The CLK input is used to synchronize the input and output serial bit streams. The data input (DI) is sampled at the rising edge of the CLK and the data output (DO) will change with the falling edge of the CLK signal. The SPI can be driven with a CLK Frequency up to 4 MHz. 4.12 Power supply failure 4.12.1 VS supply failure VS overvoltage If the supply voltages VS reaches the overvoltage threshold VSOV: LIN remains enabled CAN remains enabled OUT1 to OUT_14 are turned off (default). The shutdown of outputs may be disabled by SPI (VS_OV_SD_EN (CR 3) = 0) Charge pump is disabled (and is switched on automatically in case the supply voltage recovers to normal operating voltage) H-bridge gate driver and heater MOSFET gate driver are switched into sink condition ECV is switched in high impedance state and ECDR is discharged by RECDRDIS (to ensure the gate of the external MOSFET is discharged => EC mode considered as off) Recovery of outputs after overvoltage condition is configurable by SPI: – VS_LOCK_EN (CR 3) = 1: outputs are off until Read&Clear VS_OV (SR 2). – VS_LOCK_EN (CR 3) = 0: outputs turned on automatically after VS overvoltage condition has recovered. The overvoltage bit VS_OV (SR 2) is set and can be cleared with a ‘Read&Clear’ command. The overvoltage bit is reset automatically if VS_LOCK_EN (CR 3) = 0 and the overvoltage condition has recovered. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |