| 전자부품 데이터시트 검색엔진 |
|
ST25TB02K 데이터시트(PDF) 13 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
ST25TB02K 데이터시트(HTML) 13 Page - STMicroelectronics |
|
13 / 47 page ![]() 4.2 32-bit binary counters The two 32-bit binary counters are located at block addresses 5 and 6. The ST25TB02K uses dedicated logic that only allows the update of a counter if the new value is lower than the previous one. This feature allows the application to count down by steps of 1 or more. The initial value in Counter 5 is FFFF FFFEh and is FFFF FFFFh in Counter 6. When the reached value is 0000 0000h, the counter is empty and cannot be reloaded. For each counter 5 and 6, the update is done by issuing the Write_block command. The Write_block command writes the new 32-bit value to the counter block address. Table 6 shows examples of how the counters operate. The counter programming cycles are protected by automated antitearing logic. This function allows the counter value to be protected in case of power down within the programming cycle. In case of power down, the counter value is not updated and the previous value continues to be stored. Table 6. Binary counter (addresses 5 to 6) Block Address MSB 32-bit block LSB Description b31 b24 b23 b16 b15 b8 b7 b0 5 32-bit Boolean area Count down counter 6 32-bit Boolean area Figure 14. Countdown example (binary format) 1 ... 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ... 1 1 1 1 1 1 1 1 1 1 1 1 0 1 ... 1 1 1 1 1 1 1 1 1 1 1 0 1 Initial data 1-unit decrement 1-unit decrement b31 b0 1 ... 1 1 1 1 1 1 1 1 1 1 1 0 0 1 ... 1 1 1 1 1 1 1 1 1 0 1 0 0 1 ... 1 1 1 1 1 1 1 1 1 1 0 0 0 1-unit decrement 8-unit decrement Increment not allowed The counter with block address 6 controls the reload mode used to reset the resettable OTP area (addresses 0 to 4). Bits b31 to b21 act as an 11-bit Reload counter; whenever one of these 11 bits is updated, the ST25TB02K detects the change and adds an Erase cycle to the Write_block command for locations 0 to 4 (see the Block 0 - 4: resettable OTP area paragraph). The Erase cycle remains active until a Power-off or a Select command is issued. The ST25TB02K’s resettable OTP area can be reloaded up to 2 047 times (211-1). ST25TB02K 32-bit binary counters DS11469 - Rev 7 page 13/47 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |