F 0118G
Elektrische Werte (
T
A = 25 °C)
Electrical values
1) (T
A = 25 °C)
Bezeichnung
Parameter
Symbol
Symbol
Wert
Value
2)
Einheit
Unit
min.
typ.
max.
Emissionswellenlänge
Peak wavelength
I
F = 10 mA
λ
peak
950
nm
Spektrale Bandbreite bei 50% von
I
max,
Spectral bandwidth at 50% of
I
max
I
F = 10 mA
∆λ
55
nm
Schaltzeiten, I
e von 10% auf 90% und von 90% auf
10%, bei
I
F = 100 mA, RL = 50 Ω
Switching times, I
e from 10% to 90% and from 90%
to 10%,
I
F = 100 mA, RL = 50 Ω
t
r, tf
0.5/0.4
µs
Sperrspannung
Reverse voltage
I
R = 1µA
V
R
5V
Durchla
βspannung
Forward voltage
I
F = 100 mA
V
F
1.4
1.6
V
Strahlungsleistung
Radiant Power
3)
I
F = 100 mA
Φ
e
12
mW
Photostrom (Spezifikationsparameter Helligkeit)
Photocurrent (specified parameter brightness)
I
F = 100 mA
I
e
0.65
a.u.
1)
Measurement limits describe actual settings and do not include measurement uncertainties. Each wafer and fragment
of a wafer is subject to final testing. The wafer or its pieces are individually attached on foils (rings). Sample chips are
picked from each foil and placed on a special carrier for measurement purposes. The sampling density is one chip per
2 cm². If a sample fails, the area around that sample is tested again by taking samples in fourfold density. If a sample
fails in that measurement, an area of 0,5 cm² around each failed sample is marked by pen. All el. values are referenced
to the vendor's measurement system (correlation to customer product(s) is required)
2)
Typical (refered to as typ.) data are defined as long-term production mean values and are only given for information.
This is not a specified value
3)
Radiant power is measured on TO-18 header in integrating sphere.



Html Pages

1 2 3 4 5 6


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com