32 / 72 page ![]() NXP Semiconductors FXPS7115D4 Digital absolute pressure sensor, 40 kPa to 115 kPa Bit Symbol Description 1 DEVRES The device reset bit is set following a device reset. This error is cleared by a read of the DEVSTAT register through any communication interface or on a data transmission that includes the error in the status field.[2] 0 — Normal operation 1 — Device reset occurred 0 DEVINIT The device initialization bit is set following a device reset. The bit is cleared once sensor data is valid for read through one of the device communication interfaces (tPOR_DataValid). 0 — Normal operation 1 — Device initialization in process Table 38. DEVSTAT - device status register (address 01h) bit description...continued [1] See Section 7.7.4 bit 3, supply error reporting disable bit (SUP_ERR_DIS). [2] After POR and/or soft reset, see Section 7.5.5 for initialization sequence. 7.7.2.2 DEVSTAT1 - device status register (address 02h) Bit[1][2] 7 6 5 4 3 2 1 0 Symbol VCCUV_ ERR reserved reserved reserved INTREGA_ ERR INTREG_ ERR INTREGF_ ERR CONT_ERR Reset x x x x x x x 0 Access R R R R R R R R Table 39. DEVSTAT1 - device status register (address 02h) bit allocation [1] During POR and soft reset ignore DEVSTAT1 error flags, refer to Section 7.5.5. [2] A common timer is used for all error bits in the DEVSTAT1 register. If any supply error is present, the timer is reset to tUVOV_RCV. This bit is cleared based on the state of the SUP_ERR_DIS bit in the DEVLOCK_WR register as shown in Section 7.7.4. Bit[1][2] Symbol Description 7 VCCUV_ERR The VCC undervoltage error bit is set if the VCC voltage falls below the voltage specified in Table 104. See Section 7.1 for details on the VCC undervoltage monitor. 0 — No error detected 1 — VCC voltage low 3 INTREGA_ERR The internal analog regulator voltage out-of-range error bit is set if the internal analog regulator voltage falls outside expected limits. 0 — No error detected 1 — Internal analog regulator voltage out of range 2 INTREG_ERR The internal digital regulator voltage out-of-range error bit is set if the internal digital regulator voltage falls outside expected limits. 0 — No error detected 1 — Internal digital regulator voltage out of range 1 INTREGF_ERR The internal OTP regulator voltage out-of-range error bit is set if the internal OTP regulator voltage falls outside expected limits. 0 — No error detected 1 — Internal OTP regulator voltage out of range 0 CONT_ERR The continuity monitor passes a low current through a connection around the perimeter of the device and monitors the continuity of the connection. The error bit is set if a discontinuity is detected in the connection. Table 40. DEVSTAT1 - device status register (address 02h) bit description FXPS7115D4 All information provided in this document is subject to legal disclaimers. © 2023 NXP B.V. All rights reserved. Product data sheet Rev. 6.1 — 7 June 2023 32 / 72 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |