8 / 13 page ![]() Board Mount Pressure Sensor AMS 6915 SERIES © 2022, Analog Microelectronics GmbH www.analog-micro.com Datasheet AMS 6915 – Rev. 2.0 8/13 The I²C communication phases are as follows: Idle period (bus is free) When the bus is free, both I²C- bus lines (SDA and SCL) are pulled up to supply voltage level (“high level”). Start S (start condition) Prior to any data transfer on the bus a start condition has to be generated. The start condition is always sent by the I²C- master. The start condition is defined as a transition from “high level” to “low level” on the SDA line while the SCL line is still on “high level”. The digital data readout from the AMS 6915 is always initiated by a start condition. Stop P (stop condition) The stop condition is always generated by the I²C-master after a data transfer has been completed. The stop condition is defined as a transition from “low level” to “high level” on the SDA line while the SCL line is still on “high level”. The digital data readout from the AMS 6915 is always terminated by a stop condition. Valid data Data is transmitted in bytes (8 bits), starting with the most significant bit (MSB). One data bit is transmitted with each clock pulse. The transmitted bits are only valid when, following a start condition, the level on the SDA line is constant as long as the SCL line is on “high level”. Changes to the SDA level must be made while the SCL l ine is on “low level”. Acknowledge A After a byte has been transmitted the respective receiver (master or slave) has to send an acknowledge (additional acknowledge bit) confirming the correct receipt of the data. For this purpose the master generates an extra acknowledge-related clock pulse. The receiver sends the acknowledge bit by pulling the SDA line down to “low level” during the additional clock pulse. Addressing / Slave address (I²C-address AMS 6915) After the start condition the master sends an addressing byte (the first byte after the start condition) which determines which slave is selected. The addressing byte contains the individual 7-bit slave address of the selected slave (AMS 6915) and a data direction bit (R/ W ). A “0” for the R/ W bit indicates a transmission from master to slave (W: write; the master wishes to transmit data to the selected slave), a “1” a data request (R: read; the master requests data from the slave). The pressure sensors in the AMS 6915 series have a factory-programmed 7-bit slave address of 0x28Hex (0101000bin), which is stored in the sensor’s EEPROM. On request each AMS 6915 can be ordered with an individual 7-bit slave address programmed at the factory. Using AMS 6915 ’s USB starter kit the customer can program the individual slave address himself. In general 7-bit addressing allows 128 different addresses. If more than one AMS 6915 should be connected to the same I²C-bus, each pressure sensor requires an individual slave address. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |