| 전자부품 데이터시트 검색엔진 |
|
PS-HATSDF 데이터시트(PDF) 1 Page - Greystone Energy Systems Inc. |
|
|
|||||||||||||||||||||||||||||
PS-HATSDF 데이터시트(HTML) 1 Page - Greystone Energy Systems Inc. |
|
1 / 2 page ![]() GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM HIGH ACCURACY FLEXIBLE CABLE DUCT AVERAGE TEMPERATURE SENSOR HATSDF SERIES NOTE: The sensor accuracies listed in the specifications section apply to the sensing element only prior to product assembly and may not be reflected in the complete assembly. Due to the measurement uncertainty, it is possible, that the true resistance value of the single delivered sensor at 0°C can be out of the defined tolerance class. Profiling each assembly to take into consideration lead wire and the attachment method should be completed. PRODUCT DESCRIPTION The high accuracy flexible multi-point duct temperature sensor utilizes several precision sensors spaced at equal distances. The probe is FT-6 plenum rated cable and is available in various lengths (see ordering chart). All probes are constructed to provide excellent heat transfer and a fast response. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The flex-duct average probes are installed through a hole in the side of the duct to monitor an average temperature within the duct. Select a probe length that allows for criss-crossing the duct multiple times. Install the probes in a straight section of duct at a suitable distance downstream from any heating, cooling, or humidification devices. The cable probe needs to be fastened onto hangers using tube clamps or wire ties and should be secured every 100 cm or 3’ maximum to prevent movement of the wire and prevent wear. If sensor is to be used in high velocity or vibration environment use of rigid style duct probe is recommended. The enclosure provides mounting tabs for ease of installation. SENSOR TYPE Various Thermistor or RTD SENSOR ACCURACY RTD Class A: ±0.15°C (±0.27°F) @ 0°C (32°F) RTD 1/3 DIN: ±0.1°C (±0.18°F) @ 0°C (32°F) RTD 1/10 DIN: ±0.03°C (±0.054°F) @ 0°C (32°F) NTC Thermistor Type 39: ±0.05°C (±0.09°F), 0 to 70°C (32 to 158°F) NTC Thermistor Type 55: ±0.03°C (±0.054°F), 0 to 70°C (32 to 158°F) NTC Thermistor Type 40/46: ±0.1°C (±0.18°F), 0 to 70°C (32 to 158°F) PROBE SENSING RANGE -20 to 60°C (-4 to 140°F) AMBIENT OPERATING RANGE -40 to 50°C (-40 to 122°F) WIRE MATERIAL FT-6 rated plenum cable, 22 AWG STANDARD LENGTHS 1800, 3600, 6100, 7200mm (6’, 12’, 20’, 24’) ENCLOSURE ABS, UL94-V0, IP65 (NEMA 4X) C: includes terminal block E: same as C, with thread adapter (1/2” NPT to M16), and cable gland fitting TERMINATION A: pigtail, 2 or 3 wire C & E: terminal block, 2 or 3 wire COUNTRY OF ORIGIN Canada SPECIFICATIONS 82.5 mm 3.25" 69.8 mm 2.75" 52.0 mm 2.05" 76.2 mm 3.00" 0.5” NPT Foam Gasket 304 Series S/S Probe Various Probe Lengths See Ordering Chart FT-6 Plenum Rated Cable |
유사한 부품 번호 - PS-HATSDF |
|
유사한 설명 - PS-HATSDF |
|
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |