| 전자부품 데이터시트 검색엔진 |
|
HTDT 데이터시트(PDF) 1 Page - Greystone Energy Systems Inc. |
|
|
|||||||||||||||||||||||||||||
HTDT 데이터시트(HTML) 1 Page - Greystone Energy Systems Inc. |
|
1 / 2 page ![]() GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM DUCT HUMIDITY/TEMPERATURE TRANSMITTER HTDT SERIES CABLE GLAND FITTING THREAD ADAPTER 1/2” NPT TO M16 PRODUCT DESCRIPTION The duct temperature and humidity transmitter series uses a highly accurate and reliable Thermoset Polymer based capacitance humidity sensor and Platinum RTD temperature sensor together with state-of-the-art digital linearization and temperature compensated circuitry to monitor humidity levels. The sensors are encapsulated in a 228.60 mm (9”) long by 12.7 mm (0.5”) diameter S/S probe. A 60 micron HDPE filter protects the sensor for contaminants. A weatherproof Polycarbonate enclosure is provided for ease of installation. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The duct type probes are installed through a hole in the side of the duct to monitor a single point humidity within the duct. Install the probe in a straight section of duct at a suitable distance downstream from any heating, cooling or humidification devices. Mounting tabs on the outside of the enclosure for ease of installation. A terminal block connection is provided. for connection to the Building Automation System. HUMIDITY SENSOR TYPE Thermoset polymer based capacitive TEMPERATURE SENSOR TYPE 1000Ω Platinum, IEC 751, 385 Alpha, thin film HUMIDITY SENSOR ACCURACY ±2, 3, or 5 %RH (5 to 95 %RH) TEMPERATURE SENSOR ACCURACY ±0.1% of span SENSOR RESPONSE TIME 15 seconds typical MEASUREMENT RANGE 0 to 100 %RH HYSTERESIS ±1.5 %RH maximum REPEATABILITY ±0.5 %RH typical LINEARITY ±0.5 %RH typical OPERATING TEMPERATURE -40 to 50°C (-40 to 122°F) OPERATING HUMIDITY 0 to 95 %RH non-condensing POWER SUPPLY 18 to 35 Vdc, 15 to 26 Vac CONSUMPTION 22 mA maximum INPUT VOLTAGE EFFECT Negligible over specified operating range PROTECTION CIRCUITRY Reverse voltage protected and output limited OUTPUT SIGNAL 4-20 mA current loop, 0-5 Vdc or 0-10 Vdc (factory configured) OUTPUT DRIVE @ 24 VDC Current: 550Ω max Voltage: 10,000Ω min INTERNAL ADJUSTMENTS Clearly marked ZERO and SPAN pots ENCLOSURE B: Grey Polycarbonate, UL94-V0, IP65 (NEMA 4X) F: Same as B, with thread adapter (1/2” NPT to M16) and cable gland fitting PROBE 230mm (9”) length x 12.7mm (1/2”) diameter s/s with porous filter TERMINATION Screw terminal block (14 to 22 AWG) WEIGHT 220g (7.8 oz) including probe COUNTRY OF ORIGIN Canada SPECIFICATIONS ACCESSORIES - INCLUDED WITH F STYLE ENCLOSURE 112.5 mm 4.43" 99.7 mm 3.925" 228.60 mm 9” 116.5 mm 4.585" 0.5" NPT 304 Series S/S Probe 53.7 mm 2.115" 12.70 mm 0.50" 60 micron HDPE filter |
유사한 부품 번호 - HTDT |
|
유사한 설명 - HTDT |
|
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |