| 전자부품 데이터시트 검색엔진 |
|
2011-000002 데이터시트(PDF) 13 Page - Samsung semiconductor |
|
|
|||||||||||||||||||||||||||||
2011-000002 데이터시트(HTML) 13 Page - Samsung semiconductor |
|
13 / 43 page ![]() 4-2-3 Adjustment Procedures Use the following procedures whenever you replace the AD Board, Panel, or one or both of the Lamps. 4-2-3 (a) When Replacing the AD Board 1. Before replacing the AD Board, read all Panel information data by using the Read button on the DDC Control JIG. 2. Remove the old AD Board and replace it with a new board. 3. Perform the procedures described in section 4-2-3 (b). 4. Write the Panel information data to the new AD Board by using the Write button. 5. Perform other procedures using the DDC Control JIG, if necessary. 6. When all procedures are complete, select the Exit button ( ) to quit the DDC Control JIG software. 4-2-3 (b) Color Auto Adjustment 1. After displaying 16-Gray pattern or black and white mixed pattern, click “Color Auto Adjustment” button. 2. During normal execution of Auto Algorithm the screen image may flicker. If Auto Algorithm does not excute properly, check DDC Control JIG. 3. After normal execution of Auto Algorithm, confirm optimal settings by observing the contrast of several different patterns on the display. 4. If you want to check each color value, click the button from to and from to 4-2-3 (c) When Replacing the Panel 1. Select the Read Buffer button ( ) to gather the current information about this monitor. 2. Increment the number by clicking on the (+) button on the Panel row in the Change No. column. If they were not already 00, the numbers for the Upper and Lower Lamps will automatically change to 00. 3. Check all values. If there is an error, select Read Buffer again and increment the Change No. column to the correct number. When all values are correct, select the Write button ( ) to record the data in the firmware. 4. Select the Return Menu button ( ) to Return Main Menu. 4-2-3 (d) When Replacing the Upper and/or Lower Lamp 1. Select the Read Buffer button ( ) to gather current information about this monitor. 2. Increment the number by clicking on the (+) button on the Lamp Upper and/or Lamp Lower row in the Change No. column. 3. Check all values. If there is an error, select Read Buffer again and increment the Change No. column to the correct number(s). When all values are correct, select the Write button ( ) to record the data in the firmware. 4. Select the Return Menu button ( ) to Return Main Menu. 4 Alignments and Adjustments SyncMaster 770TFT 4-3 1 6 8 13 18 n o m n m o |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |