Back Button MA780 Datasheet HTML 23Page - Monolithic Power Systems MA780 Datasheet HTML 24Page - Monolithic Power Systems MA780 Datasheet HTML 25Page - Monolithic Power Systems MA780 Datasheet HTML 26Page - Monolithic Power Systems MA780 Datasheet HTML 27Page - Monolithic Power Systems MA780 Datasheet HTML 28Page - Monolithic Power Systems MA780 Datasheet HTML 29Page - Monolithic Power Systems MA780 Datasheet HTML 30Page - Monolithic Power Systems MA780 Datasheet HTML 31Page - Monolithic Power Systems Next Button
Zoom Inzoom in Zoom Outzoom out
 27 / 32 page
background image
MA780 – 8-BIT TO 12-BIT LOW-POWER ANGLE SENSOR
MA780 Rev. 1.2
MonolithicPower.com
27
8/30/2021
MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2021 MPS. All Rights Reserved.
APPENDIX A: DEFINITIONS
Effective Resolution
(3σ Noise Level)
Smallest angle increment distinguishable from the noise. The resolution
is measured by computing three times
σ (the standard deviation in
degrees) taken over 1,000 data points at a constant position. The bit
resolution is calculated as: log2(360 / 6σ).
Refresh Rate
Rate at which new data points are stored in the output buffer.
Latency
The time elapsed between the instant when the data is ready to be read
and the instant at which the shaft passes that position. The lag in degrees
is lag = latency x v, where v is the angular velocity (in deg/s).
Power-Up Time
Time until the sensor delivers valid data beginning at start-up (VDD <
3V).
Start-Up Time
Time until the sensor front end delivers valid data to the digital treatment
block when recovering from idle mode.
Filter Settling Time
Time for the filter to deliver a stable angle (i.e. when the error is smaller
than the noise at the particular filter window setting).
Integral Nonlinearity
(INL)
Maximum deviation between the average sensor output (at a fixed
position) and the true mechanical angle (see Figure A1).
Figure A1: Resolution, INL, Lag
INL can be obtained from the error curve err(a) = out(a) - a, where out(a)
is the average output across 1000 sensor outputs, and a is the
mechanical angle indicated by a high precision encoder (<0.001 deg).
INL can be calculated with Equation (A1):
max(err(a)) - min(err(a))
INL =
2
(A1)
Drift
The angle variation rate when one parameter is changed (e.g.
temperature, VDD) while all the others, such as the shaft angle, remain
constant.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com