13 / 18 page ![]() µPD6379, 6379A, 6379L, 6379AL 11 Data Sheet S11588EJ5V0DS • If the clock is also supplied to CLK while data is not sampled (refer to Fig. 4-1), make sure that the changing timing of LRCK coincides with the falling edge (point A) of CLK after the LSB has been input. Fig. 4-1 Input Timing Chart (1) • If the clock is supplied to CLK only while data is sampled (refer to Fig. 4-2), set the changing timing of LRCK in between the falling edge (point A) of CLK after the LSB has been input and the start of inputting the next MSB (point B) (points A and B are included). Fig. 4-2 Input Timing Chart (2) 16 Invalid Invalid LSB CLK SI 123456789 10 11 12 13 14 15 16 1 2 3 4 LRCK MSB LSB MSB A A 1 sample data period 16 Invalid Invalid LSB CLK SI 123456789 10 11 12 13 14 15 16 1 2 3 4 LRCK MSB LSB MSB A A B B 1 sample data period Changing period of LRCK Changing period of LRCK |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|