| 전자부품 데이터시트 검색엔진 |
|
M50FLW040A 데이터시트(PDF) 35 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
M50FLW040A 데이터시트(HTML) 35 Page - STMicroelectronics |
|
35 / 64 page ![]() M50FLW040A, M50FLW040BFirmware hub/low pin count (FWH/LPC) interface Configuration Reg- 35/64 6 Firmware hub/low pin count (FWH/LPC) interface Configuration Registers When the Firmware Hub Interface/Low Pin Count is selected, several additional registers can be accessed. These registers control the protection status of the Blocks, read the General Purpose Input pins and identify the memory using the manufacturer code. See Table 15 for the memory map of the Configuration Registers. The Configuration registers are accessed directly without using any specific command code. A single Bus Write or Bus Read Operation, with the appropriate address (including A22=0), is all that is needed. 6.1 Lock Registers The Lock Registers control the protection status of the Blocks. Each Block has its own Lock Register. Three bits within each Lock Register control the protection of each block: the Write Lock Bit, the Read Lock Bit and the Lock Down Bit. The Lock Registers can be read and written. Care should be taken, though, when writing. Once the Lock Down Bit is set, ‘1’, further modifications to the Lock Register cannot be made until it is cleared again by a reset or power-up. See Table 16 for details on the bit definitions of the Lock Registers. 6.1.1 Write Lock The Write Lock Bit determines whether the contents of the Block can be modified (using the Program or Erase Command). When the Write Lock Bit is set, ‘1’, the block is write protected – any operations that attempt to change the data in the block will fail, and the Status Register will report the error. When the Write Lock Bit is reset, ‘0’, the block is not write protected by the Lock Register, and may be modified, unless it is write protected by some other means. If the Top Block Lock signal, TBL, is Low, VIL, then the Top Block (Block 7) is write protected, and cannot be modified. Similarly, if the Write Protect signal, WP, is Low, VIL, then the Main Blocks (Blocks 0 to 6) are write protected, and cannot be modified. After power-up, or reset, the Write Lock Bit is always set to ‘1’ (write-protected). 6.1.2 Read Lock The Read Lock bit determines whether the contents of the Block can be read (in Read mode). When the Read Lock Bit is set, ‘1’, the block is read protected – any operation that attempts to read the contents of the block will read 00h instead. When the Read Lock Bit is reset, ‘0’, read operations are allowed in the Block, and return the value of the data that had been programmed in the block. After power-up, or reset, the Read Lock Bit is always reset to ‘0’ (not read-protected). |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |