| 전자부품 데이터시트 검색엔진 |
|
MAS9116 데이터시트(PDF) 6 Page - Micro Analog systems |
|
|
|||||||||||||||||||||||||||||
MAS9116 데이터시트(HTML) 6 Page - Micro Analog systems |
|
6 / 18 page ![]() 6 (18) DA9116.005 22 November, 2005 TEST REGISTER CR5 DESCRIPTION Note: Test register is intended only for internal testing of the device and not supposed to be used in normal operation. It is strongly recommended not to change initial test register value (00hex). XMUTE pin is output pin when bit 1 is set in register CR5. Bits 2, 3 and 4 select different internal signals. In test phase those signals can be seen via XMUTE pin. Condition Data Byte bits Function 7 6 5 4 3 2 1 0 XMUTE=in 0 0 0 0 0 0 0 0 Normal operation Test, XMUTE=in 0 0 0 0 0 0 0 1 Force latch, note 1 Test, XMUTE=out 0 0 0 0 0 0 1 0 left delay generator Test, XMUTE=out 0 0 0 0 0 1 1 0 left peak detector Test, XMUTE=out 0 0 0 0 1 0 1 0 left zero crossing Test, XMUTE=out 0 0 0 0 1 1 1 0 left enable for zero crossing and delay generator Test, XMUTE=out 0 0 0 1 0 0 1 0 right delay generator Test, XMUTE=out 0 0 0 1 0 1 1 0 right peak detector Test, XMUTE=out 0 0 0 1 1 0 1 0 right zero crossing Test, XMUTE=out 0 0 0 1 1 1 1 0 right enable for zero crossing and delay generator Note 1. Forces the new gain value to be latched to resistor network without waiting for zero crossing or delay generator. LSB bit has to be returned to 0 before next gain value can be latched. When force latch is used, both channels are latched with the same value. ABSOLUTE MAXIMUM RATINGS All voltages with respect to ground. Parameter Symbol Conditions Min Max Unit Signal Voltage RIN, RFO, LIN, LFO -20 +20 V Positive Supply Voltage AVCC, DVCC -0.5 +6.0 V All other pins -0.3 AVCC +0.3 Storage Temperature TS -55 +125 oC Operating Temperature TA -40 +85 oC ESD (HBM) pins 3, 4, 13 and 14 300 V ESD (HBM) all other pins 2000 V Stresses beyond those listed may cause permanent damage to the device. The device may not operate under these conditions, but it will not be destroyed. RECOMMENDED OPERATION CONDITIONS (AVCC=+5.0 V, AVSS=0 V, TA=+25 oC unless otherwise noted) Parameter Symbol Conditions Min Typ Max Unit Signal Voltage RIN, RFO, LIN, LFO -18 +18 V Positive Supply Voltage AVCC,DVCC 4.5 5 5.5 V Negative Supply Voltage AGND,DGND 0 V Signal Grounds LGND,RGND 0 V Operating Temperature TA -20 +25 +60 oC |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |