| 전자부품 데이터시트 검색엔진 |
|
GV2AP02 데이터시트(PDF) 29 Page - Schneider Electric |
|
|
|||||||||||||||||||||||||||||
GV2AP02 데이터시트(HTML) 29 Page - Schneider Electric |
|
29 / 48 page ![]() 28 1 2 VW3A4422 + ATV320U04N4B 3 4 VW3A4424 + ATV320U55N4B Presentation Variable speed drives Altivar Machine ATV320 Additional EMC input filters Presentation: page 4 Variable speed drives: page 12 Combinations: page 22 Dimensions: page 44 Presentation Additional EMC input filters The additional EMC input filters enable the drives to meet more stringent requirements; they are designed to reduce conducted emissions on the supply mains below the limits of standard IEC 61800-3 category C1 or C2 (see below). Mounting on ATV320ppppB v Depending on the model, additional EMC filters can be mounted beside or underneath the drive. v They act as a support for the drives and are attached to them via tapped holes. Mounting the filter on the side of the drive: 1 ATV320pppM2B, ATV320U04N4B…U40N4B drives 2 Additional EMC input filters Mounting the filter underneath the drive: 3 ATV320U55N4B…U75N4B and ATV320D11N4B…D15N4B drives 4 Additional EMC input filters Mounting on ATV320ppppC Additional EMC filters can be mounted beside or underneath the ATV320pppppC drives, except for the ATV320pppS6C drives. They act as a support for the drives and are attached to them via tapped holes. Use according to the type of supply mains v Additional EMC filters can only be used on TN (neutral connection) and TT (grounded neutral) type systems. v Standard IEC 61800-3, appendix D2.1, states that on IT systems (isolated or impedance grounded neutral), filters can cause permanent insulation monitors to operate in a random manner. v The effectiveness of additional filters on this type of system depends on the type of impedance between neutral and ground, and therefore cannot be predicted. v If a machine has to be installed on an IT system, one solution is to insert an isolation transformer and connect the machine locally on a TN or TT system. v The radio interference input filters integrated in Altivar 320 drives can easily be disconnected by means of a selector switch without removing the drive. 2 1 3 4 5 6 7 8 9 10 2 1 3 4 5 6 7 8 9 10 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |