| 전자부품 데이터시트 검색엔진 |
|
TS4975 데이터시트(PDF) 23 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
TS4975 데이터시트(HTML) 23 Page - STMicroelectronics |
|
23 / 36 page ![]() TS4975 Application Information 23/36 All bytes are sent with MSB bit first. The transfer of written data ends with a “stop” message. When transmitting several data, the data can be written with no need to repeat the “start” message and addressing byte with the slave address. In order to read data from the TS4975, after the “start” message, the MCU must send and receive the following data: ● send byte with the I²C 7-bit slave address and with a high level for the R/W bit ● receive the data (control register value) All bytes are read with MSB bit first. The transfer of read data is ended with “stop” message. When transmitting several data, the data can be read with no need to repeat the “start” message and the byte with slave address. In this case the value of control register is read repeatedly. When the thermo shutdown or pop and click reduction is active, specific values are read from the TS4975 (see Section 4.9: Pop and click performance on page 31 and Section 4.10: Thermo shutdown on page 32). Figure 59. I²C write/read operations Table 10. Ouput mode selection: G from -34 dB to + 18dB (by steps of 4dB)(1) 1. SD = Shutdown Mode In1 = Audio Input 1 In2= Audio Input2 G = Gain from Audio Input 1and Input 2 to Output1 and Output2 Output Mode # Headphone Output 1 Headphone Output 2 0SD SD 1 G x In1 G x In2 2 G x In2 G x In1 3 G x In1 G x In1 4 G x In2 G x In2 5SD G x In1 6SD G x In2 7 G x In1 SD 8 G x In2 SD SDA S1 1 0 0 A0 0 A 1 1 D7 D6 D5 D4 D2 D3 D0 D1 A P Start condition SLAVE ADDRESS CONTROL REGISTERS R/W Acknowledge from Slave Acknowledge from Slave Stop condition Volume Control settings Output Mode settings Phantom Ground settings SDA S1 1 0 0 A0 0 A 1 1 D7 D6 D5 D4 D2 D3 D0 D1 A P S1 1 0 0 A0 0 A 1 1 D7 D6 D5 D4 D2 D3 D0 D1 A P Start condition SLAVE ADDRESS CONTROL REGISTERS R/W R/W Acknowledge from Slave Acknowledge from Slave Stop condition Volume Control settings Output Mode settings Phantom Ground settings |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |