Back Button 8137 Datasheet HTML 4Page - Christian Bürkert GmbH & Co. KG 8137 Datasheet HTML 5Page - Christian Bürkert GmbH & Co. KG 8137 Datasheet HTML 6Page - Christian Bürkert GmbH & Co. KG 8137 Datasheet HTML 7Page - Christian Bürkert GmbH & Co. KG 8137 Datasheet HTML 8Page - Christian Bürkert GmbH & Co. KG 8137 Datasheet HTML 9Page - Christian Bürkert GmbH & Co. KG 8137 Datasheet HTML 10Page - Christian Bürkert GmbH & Co. KG 8137 Datasheet HTML 11Page - Christian Bürkert GmbH & Co. KG 8137 Datasheet HTML 12Page - Christian Bürkert GmbH & Co. KG  
Zoom Inzoom in Zoom Outzoom out
 9 / 12 page
background image
Type 8137
9 | 12
Visit product website 
6.2. Product operation notes
Operating techniques
The measuring device provides different operating techniques:
• the display/configuration module
• the suitable Bürkert DTM in conjunction with adjustment software according to the FDT/DTM standard, e.g. PACTware™ and PC
• a HART handheld
The entered parameters are generally saved in the measuring device Type 8137. Optionally, parameters may also be uploaded and
downloaded with the display/configuration module or saved in a file by using PACTware™/8137-DTM.
Set up with display/configuration module
Display/configuration module
Description
The display/configuration module can be inserted into the measuring device and removed
again at any time. It is not necessary to interrupt the power supply. The measuring device is
adjusted via the four keys of the display/configuration module.
Set up with PACTware™/DTM and HART communication
Assembly
Description
~
=
PACTwareTM
Bürkert DTM
Power supply unit
1
2
3
The measuring device can be operated thanks to PACTware™, via
HART communication. An interface adapter is necessary for the
adjustment with PACTware™. For the setup of the Type 8137, the
DTM in the actual version must be used. The basic version of DTM
incl. PACTware™ is available as a free-of-charge download from
the internet at www.burkert.com .
Connecting the PC via HART
No. Description
1
Measuring device Type 8137
2
HART-USB Modem
3
Resistance 250 Ω
Necessary components:
• Measuring device Type 8137
• PC with PACTware™ and suitable Bürkert DTM
• HART-USB Modem
• Resistance approx. 250 Ω
• Power supply unit



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com