7 / 11 page ![]() Type 8412 7 | 11 Visit product website 5. Product operation 5.1. Functional overview Temperature T A/D Calibration Sensor monitoring Scaling Fine adjustment Filters Decimal places Measuring range monitoring Min./Max. indicator Date/Name Device functions (Profile DS 404) EMERGENCY PDO HEARTBEAT SYNC NMT LSS 1 2 3 4 5 6 7 8 9 10 11 Probe break/ Probe short-circuit Measured value, 32 bit Status, 8 bit Parameters Measured values Status 12 SDO 13 14 15 16 17 No. Description 1 The measured temperature value is digitized. 2 The temperature signal is adjusted digitally per default. 3 The sensor monitoring continuously checks the correct function of the sensor signal and triggers high-priority emergency frames in the event of an error. 4 The measured temperature value can be scaled to any measuring units (or in % of the measuring range). 5 The fine adjustment features a freely adjustable characteristic line offset. 6 Undesired signal fluctuations can be suppressed using the adjustable filter constant. 7 The measurement output has a freely selectable decimal place. 8 Free choice of upper and lower limits for range monitoring. The result is given as a status byte in addition to the measurement in the PDO frame. 9 The drag pointer (“min./max. index”) function records the minimum and maximum temperature values. 10 The date and name of the last maintenance operation can be saved. 11 The emergency frame is triggered in the event of a sensor fault. 12 The PDO frame contains a 32-bit measurement and a 8-bit status. The measurement output can be controlled by means of different trigger conditions. 13 SDO frames can be used to set parameters and to request measured values and statuses. 14 The heartbeat signal can be used to additionally monitor the function of the transmitter. 15 The sync command can also be used to control the transfer of the measured values. 16 The NMT frames are for the purpose of controlling the operating status of the transmitter. 17 The CAN Node ID and the CAN baud rate are set either with LSS or SDO. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |