4 / 19 page ![]() 4 Preliminary Rev 1.1a © 2021 Sendyne Corp Sendyne SIM100MLP Safety of the IT power system V n V b V p V n V b V p Chassis V n V b V p V n V b V p Chassis Chassis Figure 1: The IT power system topology Figure 3: In a “symmetrical” isolation fault V n = Vp V n V b V p V n V b V p Chassis Chassis Figure 2: Single isolation fault Ungrounded, unearthed, “floating” or IT (Isolé terr e or Isolated Terra) are all terms used to describe power systems that have no intentional conductive connec- tion to earth’s or chassis ground. The main advantage of the IT power system is that a single “short” will not disable its ability to continue delivering power. Figure 1 illustrates the basic topology of such a system. The resistive connections, shown in Fig 1, between the terminals of the power source and the chassis are referred to as the “isolation resistances” ( R ISO,P and R ISO,N ) and they represent the parallel combination of all resistive paths from the power source terminals to the chassis (including the ones the isolation monitor introduces). The values of isolation resistances are desirable to be high so leakage currents that travel through them are kept to a harmless minimum. The capacitors shown represent the parallel combination of all capacitances present, including the Y-capacitors typically used in DC IT systems to suppress EMI. The values of Y-capacitors are kept within limits in order to avoid hazardous accumulation of energy. The volt- ages V p and Vn are shown each to be equal with half the battery voltage, which will be the case if the values of R ISO,P and RISO,N are equal. Isolation faults If either of the isolation resistances decreases below the threshold of 100 Ohms/Volt a hazard occurs if a person makes contact with the terminal “opposite” to the leaking resistor. This hazardous situation is il- lustrated in Figure 2. V n V b V p V n V b V p Chassis Figure 4: An isolation fault may originate from any point within a battery pack |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |