Back Button AS6221T Datasheet HTML 18Page - OSRAM GmbH AS6221T Datasheet HTML 19Page - OSRAM GmbH AS6221T Datasheet HTML 20Page - OSRAM GmbH AS6221T Datasheet HTML 21Page - OSRAM GmbH AS6221T Datasheet HTML 22Page - OSRAM GmbH AS6221T Datasheet HTML 23Page - OSRAM GmbH AS6221T Datasheet HTML 24Page - OSRAM GmbH AS6221T Datasheet HTML 25Page - OSRAM GmbH AS6221T Datasheet HTML 26Page - OSRAM GmbH Next Button
Zoom Inzoom in Zoom Outzoom out
 22 / 36 page
background image
AS6221T
Register description
Datasheet
• PUBLIC • Document Feedback
DS001032
• v3-00 • 2023-Oct-13
22 / 36
/
Example 50 °C:
50°������/0.0078125°������ = 6400 = ������������������������������������ 0001 1001 0000 0000 = ������������������ 1900
Table 20: Temperature conversion examples
Temperature (°C)
Digital output (Binary)
Digital output (Hex)
60.0
0001 1110 0000 0000
1E00
50.0
0001 1001 0000 0000
1900
25.0
0000 1100 1000 0000
0C80
0.125
0000 0000 0001 0000
0010
0.0078125
0000 0000 0000 0001
0001
0.0
0000 0000 0000 0000
0000
6.3
Serial interface
The device employs a standard I²C-serial bus.
6.3.1
Bus description
A data transfer must be invoked by a master device (e.g. microcontroller) which defines the
access to the slave device. The master device defines and generates the serial clock (SCL)
and the start/stop conditions.
In order to address a specific device, a START condition has to be generated by the master
device by pulling the data line (SDA) from a logic high level to a logic low level while the serial
clock signal (SCL) is kept at high level.
After the start condition, the slave address byte is transmitted which is completed with a ninth
bit which indicates a read (bit=’1’) or a write operation (bit=’0’) respectively. All slaves read the
data on the rising edge of the clock. An acknowledge signal is generated by the addressed
slave during the ninth clock pulse. This acknowledge signal is produced by pulling the pin SDA
to a low level by the selected slave.
Subsequently, the byte data transfer is started and finished by an acknowledge bit. A change
in the data signal (SDA) while the clock signal (SCL) is high causes a START or STOP
condition. Hence, it must be ensured such a condition is prevented during a data transfer
phase.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com