3 / 11 page ![]() DMR35-ACV Series AC Voltmeter DMR35-ACV.A01.D04 Page 3 of 11 www.murata-ps.com SPECIFICATIONS: Measurement Performance Min Typ. Max Units Measurement Ranges DMR35-ACV1 0-5, 0-10, 0-15, 0-25 VAC DMR35-ACV2 0-50, 0-150, 0-250, 0-300 VAC Accuracy (25 °C) 60 Hz sinusoidal input 1 % Reading +4 counts Measurement Modes Mean Reading (Average) and True RMS, DIP Switch selectable Measurement Frequency Range 1 20 120 Hz Measurement Crest Factor 3 Temperature Stability (full-scale measurement) 0.02 % /°C Input Impedance DMR35-ACV1 100 kΩ DMR35-ACV2 1 MΩ Isolation/Hipot (power input terminals to measurement input terminals)2 2150 VDC 1 Frequency range over which measurement is stable to within ±1% with sinusoidal input 2 100% Tested in production, applied for 2 seconds Power Supply Characteristics Min Typ. Max Units Power Supply Voltage 100 264 VAC Power Supply Frequency 47 63 Hz Power Supply Current …at 120 VAC 15 mA …at 240 VAC 10 mA Display & User Interface Display Type & Size 3-1/2 digit 7-segment, 11.4mm (0.45 in.) high 21 segment curved bar-graph Display Color Red (625nm) Decimal Point Selection Automatic Out-of-range Indication Flashing display Measurement Range Selection Dipswitch selectable (4 ranges) Measurement Mode Selection Dipswitch selectable (Average-reading or RMS) Display Intensity Control Dipswitch selectable (4 ranges) Terminal Blocks Wire Size 14-24 AWG Insulation Strip Length 6mm (0.24 in.) Screw Tightening Torque 0.4 N-m (3.5 lb.-in) Operating Temperature4 0 50 °C Storage Temperature -40 70 °C Humidity (non-condensing) 0 85 %RH Sealing (front face, when installed with included gasket) Splash and dust resistant Mounting screws (4 included) #4-20 0.5” thread forming Screw Tightening Torque 9 in-lb (1 N-m) Panel thickness when used with included mounting screws 0.062 in. (1.6mm) 0.25 in. (6.3mm) Weight 2.5 (71) oz. (g) 4 Maximum operating temperature applies to both front face and rear of housing. Unit must not be installed so that the rear of housing is exposed to more than the maximum operating temperature when powered. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |