| 전자부품 데이터시트 검색엔진 |
|
PMP71 데이터시트(PDF) 13 Page - Endress+Hauser Group Services AG |
|
|
|||||||||||||||||||||||||||||
PMP71 데이터시트(HTML) 13 Page - Endress+Hauser Group Services AG |
|
13 / 124 page ![]() Cerabar S PMC71, PMP71, PMP75 Endress+Hauser 13 PMP71 and PMP75 – metallic process isolating diaphragm for gauge pressure Nominal value Range limit Lowest calibratable Span 1) MWP OPL Vacuum resistance 2) Option 3) lower (LRL) upper (URL) Silicone oil/ Inert oil [bar (psi)] [bar (psi)] [bar (psi)] [bar (psi)] [bar (psi)] [barabs (psiabs)] 400 mbar (6 psi) –0.4 (–6) +0.4 (+6) 0.005 (0.075) 4 (60) 6 (90) 0.01/0.04 (0.15/0.6) 1F 1 bar (15 psi) –1 (–15) +1 (+15) 0.01 (0.15) 6.7 (100) 10 (150) 1H 2 bar (30 psi) –1 (–15) +2 (+30) 0.02 (0.3) 13.3 (200) 20 (300) 1K 4 bar (60 psi) –1 (–15) +4 (+60) 0.04 (0.6) 18.7 (280.5) 28 (420) 1M 10 bar (150 psi) –1 (–15) +10 (+150) 0.1 (1.5) 26.7 (400.5) 40 (600) 1P 40 bar (600 psi) –1 (–15) +40 (+600) 0.4 (6) 100 (1500) 160 (2400) 1S 100 bar (1500 psi) –1 (–15) +100 (+1500) 1.0 (15) 100 (1500) 400 (6000) 1U 400 bar (6000 psi) –1 (–15) +400 (+6000) 4.0 (60) 400 (6000) 600 (9000) 1W 700 bar (10500 psi) 4) –1 (–15) +700 (+10500) 7.0 (105) 700 (10500) 1050 (15750) 1X 1) Turndown > 100:1 on request or can be set on device 2) The vacuum resistance applies to the measuring cell under reference operating conditions. In the case of the PMP75, the pressure and temperature application limits of the selected filling oil must also be observed → 109. 3) Product Configurator, order code for "Sensor range; sensor over pressure limit" 4) PMP71 only, PMP75 on request PMP71 and PMP75 – metallic process isolating diaphragm for absolute pressure Nominal value Range limit Lowest calibratable Span 1) MWP OPL Vacuum resistance 2) Option 3) lower (LRL) upper (URL) Silicone oil/ Inert oil [barabs (psiabs)] [barabs (psiabs)] [bar (psi)] [barabs (psiabs)] [barabs (psiabs)] [barabs (psiabs)] 400 mbar (6 psi) 0 +0.4 (+6) 0.005 (0.075) 4 (60) 6 (90) 0.01/0.04 (0.15/0.6) 2F 1 bar (15 psi) 0 +1 (+15) 0.01 (0.15) 6.7 (100) 10 (150) 2H 2 bar (30 psi) 0 +2 (+30) 0.02 (0.3) 13.3 (200) 20 (300) 2K 4 bar (60 psi) 0 +4 (+60) 0.04 (0.6) 18.7 (280.5) 28 (420) 2M 10 bar (150 psi) 0 +10 (+150) 0.1 (1.5) 26.7 (400.5) 40 (600) 2P 40 bar (600 psi) 0 +40 (+600) 0.4 (6) 100 (1500) 160 (2400) 2S 100 bar (1500 psi) 0 +100 (+1500) 1.0 (15) 100 (1500) 400 (6000) 2U 400 bar (6000 psi) 0 +400 (+6000) 4.0 (60) 400 (6000) 600 (9000) 2W 700 bar (10500 psi) 4) 0 +700 (+10500) 7.0 (105) 700 (10500) 1050 (15750) 2X 1) Turndown > 100:1 on request or can be set on device 2) The vacuum resistance applies to the measuring cell under reference operating conditions. In the case of the PMP75, the pressure and temperature application limits of the selected filling oil must also be observed → 109. 3) Product Configurator, order code for "Sensor range; sensor over pressure limit" 4) PMP71 only, PMP75 on request |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |