MAAMSS0057SMB 데이터시트(PDF) 3 Page - Tyco Electronics

부품명 MAAMSS0057SMB
상세설명  RF Driver Amplifier 250 - 4000 MHz
PDF  4 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  MACOM [Tyco Electronics]
홈페이지  http://www.macom.com
Logo MACOM - Tyco Electronics

MAAMSS0057SMB 데이터시트(HTML) 3 Page - Tyco Electronics

  MAAMSS0057SMB Datasheet HTML 1Page - Tyco Electronics MAAMSS0057SMB Datasheet HTML 2Page - Tyco Electronics MAAMSS0057SMB Datasheet HTML 3Page - Tyco Electronics MAAMSS0057SMB Datasheet HTML 4Page - Tyco Electronics  
Zoom Inzoom in Zoom Outzoom out
 3 / 4 page
background image
RF Driver Amplifier
250 - 4000 MHz
MAAMSS0057
M/A-COM Inc. and its affiliates reserve the right to make changes to the
product(s) or information contained herein without notice. M/A-COM makes
no warranty, representation or guarantee regarding the suitability of its
products for any particular purpose, nor does M/A-COM assume any liability
whatsoever arising out of the use or application of any product(s) or
information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
V2
3
RoHS
Compliant
2140 MHz Schematic
2140 MHz PCB Layout
Parts List
Part
Value
Case Style
Manufacturer
Purpose
C1
1000 pF
0402
Murata
DC Block
C2
1.5 pF
0402
Murata
Input Tuning
C3
1000 pF
0402
Murata
Bypass
C4
0.1 μF
0402
Murata
Bypass
C5
1.5 pF
0402
Murata
Inter-stage Tuning
C6
0.1 μF
0402
Murata
Bypass
C7
1000 pF
0402
Murata
Bypass
C8
1000 pF
0402
Murata
Output Tuning
C9
1.2 pF
0402
Murata
Inter-stage Tuning
C10
1.2 pF
0402
Murata
Inter-stage Tuning
C11
3.3 μF
1206
Murata
Bypass
L1
2.7 nH
0402
Coilcraft
Input Tuning
L2
7.5 nH
0402
Coilcraft
Bias Injection
L3
8.2 nH
0402
Coilcraft
Bias Injection
J1
Jumper
-
-
Jumper
J2
Jumper
-
-
Jumper
Cross Section View
The PCB dielectric between RF traces and RF ground lay-
ers should be chosen to reduce RF discontinuities between
50 Ω lines and package pins. M/A-COM recommends an
FR-4 dielectric thickness of 0.008” (0.20 mm) yielding a 50
Ω line width of 0.015” (0.38 mm). The recommended RF
metalization is 1 ounce copper.
Handling Procedures
Please observe the following precautions to avoid
damage:
Static Sensitivity
Gallium Arsenide Integrated Circuits are sensitive
to electrostatic discharge (ESD) and can be
damaged by static electricity. Proper ESD control
techniques should be used when handling these
devices.



Html Pages

1 2 3 4


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com