| 전자부품 데이터시트 검색엔진 |
|
SP6659 데이터시트(PDF) 7 Page - Sipex Corporation |
|
|
|||||||||||||||||||||||||||||
SP6659 데이터시트(HTML) 7 Page - Sipex Corporation |
|
7 / 11 page ![]() 7 Date: 9/25/06 Rev C SP6659 1.5MHz, 600mA Synchronous Buck Regulator © 2006 Sipex Corporation Figure 21. SP6659 Idle Mode Operation APPLICATION INFORMATION A resistive divider based on the following equation determines the output voltage: VOUT = 0.6 (1+ ) The external resistive divider is connected to the output as shown in Figure 20 . ® SP6659 GND R1 R2 VFB VOUT Figure 20: Setting the SP6659 Output Voltage. R1 R2 The SP6659 is a monolithic switching mode Step-Down DC-DC converter. It utilizes in- ternal MOSFETs to achieve high efficiency and can generate very low output voltage by using its internal reference at 0.6V. It operates at a fixed switching frequency, and uses slope compensated, current-mode architecture. This Step-Down DC-DC con- verter supplies 600mA of output current at VIN = 3V. The entire input voltage range is from 2.5V to 5.5V. __________________ CURRENT MODE PWM CONTROL Slope compensated current mode PWM control provides stable switching and cycle- by-cycle current limit for excellent load and line responses and protection of the internal main switch (P-Channel MOSFET) as well as the synchronous rectifier (N-Channel MOSFET). During normal operation, the in- ternal P-Channel MOSFET is turned on for a certain time to ramp the inductor current at each rising edge of the internal oscillator, and switched off when the peak inductor current is above the error voltage. The current comparator, ICOMP, limits the peak inductor current. When the main switch is off, the synchronous rectifier will be turned THEORY OF OPERATION on immediately and stay on until either the inductor current starts to reverse, as indi- cated by the current reversal comparator, IZERO, or the beginning of the next clock cycle. The OVDET comparator controls output transient overshoots by turning the main switch off and keeping it off until the fault is no longer present. _______________________ IDLE MODE OPERATION At very light loads, the SP6659 automati- cally enters Idle Mode (Figure 21). _____________________ SETTING THE OUTPUT VOLTAGE |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |