전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

SP7662ERL/TR 데이터시트(PDF) 8 Page - Sipex Corporation

부품명 SP7662ERL/TR
상세설명  Wide Input Voltage Range 12A, 300kHz, Buck Regulator
PDF  19 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  SIPEX [Sipex Corporation]
홈페이지  http://www.sipex.com
Logo SIPEX - Sipex Corporation

SP7662ERL/TR 데이터시트(HTML) 8 Page - Sipex Corporation

Back Button SP7662ERL/TR Datasheet HTML 4Page - Sipex Corporation SP7662ERL/TR Datasheet HTML 5Page - Sipex Corporation SP7662ERL/TR Datasheet HTML 6Page - Sipex Corporation SP7662ERL/TR Datasheet HTML 7Page - Sipex Corporation SP7662ERL/TR Datasheet HTML 8Page - Sipex Corporation SP7662ERL/TR Datasheet HTML 9Page - Sipex Corporation SP7662ERL/TR Datasheet HTML 10Page - Sipex Corporation SP7662ERL/TR Datasheet HTML 11Page - Sipex Corporation SP7662ERL/TR Datasheet HTML 12Page - Sipex Corporation Next Button
Zoom Inzoom in Zoom Outzoom out
 8 / 19 page
background image
8
Mar -07 Rev AJ
SP7662 Wide Input Voltage Range 2A, 300kHz Buck Regulator
© 2007 Sipex Corporation
SolvingforR9weget:
R9 = [60mV • (R3 + R4)]
[(IMAx • DCR) – 60mV]
Asanexample:ifdesiredIMAx is 7A, then
R9 = 63.4KΩ.
R9
63.4KΩ
CSP
6.8nF
SWN
ISP
ISN
SP7662
CS
0.uF
R4
5.11KΩ
R3
5.11KΩ
L=2.7uH,DCR=4.1mΩ
VOUT
Over-current detection circuit for
Imax > 60mV / DCR
Decreasing the Current Limit
If it is required to set IMAx < {60mV / DCR,
a resistor is added as shown in the follow-
ing figure. R8increases the net voltage
detected by the current-sense comparator.
Voltage at the positive and negative terminal
ofcomparatorisgivenby:
VSP = VOut + (IMAx • DCR)
VSN = VOut
{R8 / (R4 +R8)}
Sincethecomparatoristriggeredat60mV:
VSP-VSN = 60 mV
Combining the above equations and solv-
ingforR8:
R8 =
R4 •
[VOut- 60mV + (IMAX • DCR)]
60mV - (IMAX • DCR)
Asanexample:forIMAx of 2A and VOut of
3.3V,calculatedR8is1.5MΩ.
CSP
6.8nF
ISN
SP7662
SWN
ISP
CS
0.uF
R4
5.11KΩ
R3
5.11KΩ
VOUT
L=2.7uH,DCR=4.1mΩ
R8
1.5MΩ
Over-current detection circuit for
Imax < {60mV / DCR}
Handling of Faults
Upon the detection of power (UVLO), ther-
mal, or short-circuit faults, the SP7662 is
forced into an idle state where the SS and
COMPpinsarepulledlowandbothswitches
are held off. In the event of UVLO fault, the
SP7662 remains in this idle state until the
UVLO fault is removed. Upon the detection
of a thermal or short-circuit fault, an internal
200ms timer is activated. In the event of a
short-circuit fault, a restart is attempted im-
mediately after the 200ms timeout expires.
Whereas, when a thermal fault is detected
the200msdelaycontinuouslyrecyclesanda
restartcannotbeattempteduntilthethermal
fault is removed and the timer expires.
THEORY OF OPERATION



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com