| 전자부품 데이터시트 검색엔진 |
|
P1-32/I2/SVB 데이터시트(PDF) 4 Page - Eaton All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
P1-32/I2/SVB 데이터시트(HTML) 4 Page - Eaton All Rights Reserved. |
|
4 / 6 page ![]() 02/26/2015 207314 - HPL-ED2014 V9.0 EN 4 / 6 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TechnicaldataETIM5.0 Low-voltage industrial components (EG000017) / Switch disconnector (EC000216) Electric engineering, automation, process control engineering / Low-voltage switch technology / Off-load switch, circuit breaker, control switch / Switch disconnector (ecl@ss8-27-37-14-03 [AKF060009]) Version as switch disconnector compact Yes Version as main switch Yes Version as maintenance-/service switch Yes Version as safety switch No Version as emergency stop installation Yes Max. rated operation voltage Ue AC V 690 Rated permanent current Iu A 32 Rated operation power AC-3, 400 V kW 13 Rated operation power at AC-23, 400 V kW 15 Conditioned rated short-circuit current Iq kA 80 Number of poles 3 Number of auxiliary contacts as normally closed contact 0 Number of auxiliary contacts as normally open contact 0 Number of auxiliary contacts as change-over contact 0 Motor drive optional No Motor drive integrated No Voltage release optional No Device construction Complete device in housing Suitable for ground mounting Yes Suitable for front mounting No Suitable for front mounting center No Suitable for distribution board installation No Suitable for intermediate mounting No Type of control element - Interlockable Yes Connection type main current circuit Screw connection Degree of protection (IP), front side IP65 Approvals Product Standards UL 508; CSA-C22.2 No. 14-05; CSA-C22.2 No. 94; IEC/EN 60947-3; CE marking UL File No. E36332 UL Category Control No. NLRV CSA File No. 12528 CSA Class No. 3211-05 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |