23 / 31 page ![]() Figure 47. HBM JEDEC (left) and IEC61000-4-2 (right) pulses The IEC61000-4-2 standard is more severe than the HBM ESD test and significantly increases the robustness of the equipment. IEC61000-4-2 8 kV protections are commonly implemented. The ST4E1216 and ST4E1240 furthermore increase the robustness of systems thanks to the dedicated IEC61000-4-2 12 kV protections on bus terminals A and B. There are two methods of ESD testing: contact discharge and air discharge. In the contact discharge method, the electrode of the test generator is held in contact with an exposed conductor on the equipment under test (EUT). In the air discharge, the electrode of the generator is moved from a distance towards the EUT until an arc occurs. The contact discharge offers the best reproducibility and is chosen to be the test method for IEC61000-4-2. The ST4E1216 and ST4E1240 comply with IEC61000-4-2 12 kV contact discharge. ST4E1216, ST4E1240 Detailed description DS14542 - Rev 2 page 23/31 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|