22 / 32 page ![]() 5 W Universal Input Dual Output Isolated TNY266 03-April-2001 8.6 Conducted EMI Scans The attached plots show worst-case EMI performance for EP8 as compared to CISPR22B conducted emissions limits. Peak detection is commonly used for initial diagnosis of EMI, as full frequency range results can be quickly obtained, using a common spectrum analyzer. This is also a worst-case form of analysis, as the CISPR22B limits are based on quasi-peak and average detection, both of which give lower amplitude results than peak detection. For EMI and safety techniques refer to PI application note AN15 (Figure 6 shows a typical test set up). Quasi-peak Average Figure 8.6.1 - EP9, TNY266, L, N, 120 VAC, Full Load, CISPR Limits. Figure 8.6.2 - EP9, TNY266, L, N, 230 VAC, Full Load, CISPR Limits. Page 22 of 32 Power Integrations, Inc. Tel: +1 408 414 9200 Fax: +1 408 414 9201 www.powerint.com |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|