| 전자부품 데이터시트 검색엔진 |
|
TDA4841PS 데이터시트(PDF) 13 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
TDA4841PS 데이터시트(HTML) 13 Page - NXP Semiconductors |
|
13 / 60 page ![]() 1999 Oct 25 13 Philips Semiconductors Product specification I2C-bus autosync deflection controller for PC monitors TDA4841PS Table 3 Activation of protection mode When the protection mode is active, several pins of the TDA4841PS are forced into a defined state: HDRV (horizontal driver output) is floating BDRV (B+ control driver output) is floating HUNLOCK (indicates, that the frequency-to-voltage converter is out of lock) is floating (HIGH via external pull-up resistor) CLBL provides a continuous blanking signal VOUT1 and VOUT2 (vertical outputs) are floating The capacitor at HPLL2 is discharged. If the soft start procedure is activated via the I2C-bus, all of these actions will be performed in a well defined sequence (see Figs 22 and 23). ACTIVATION RESET Low supply voltage at pin 10 increase supply voltage, reload registers, soft start via I2C-bus Power dip, below 8.1 V reload registers, soft start via I2C-bus or via supply voltage X-ray protection XRAY (pin 2) triggered reload registers, soft start via I2C-bus HPLL2 (pin 30) externally pulled to ground release pin 30 Power dip recognition In standby mode the I2C-bus will only answer with an acknowledge when data is sent to the control register 1AH. This register contains the standby and soft start control bit. If the I2C-bus master transmits data to another register, an acknowledge is given after the chip address and the subaddress; an acknowledge is not given after the data. This indicates that data can be stored into normal registers only in soft start mode. If the supply voltage drops below 8.1 V the deflection controller leaves normal operation and changes to standby mode. The microcontroller can check this state by sending data into a register with the subaddress 0XH. The acknowledge will only be given on the data if the IC is active. Due to this behaviour the start-up of the TDA4841PS is defined as follows: the first data that is transferred to the deflection controller must be sent to the control register with subaddress 1AH. Any other subaddress will not lead to an acknowledge. This is a limitation in checking the I2C-busses of the monitor during start-up. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |