12 / 88 page ![]() Figure 6. State diagram Power-down Mode Ready Mode POR en = 1 Wake-up Mode en = 0 Reset Mode RESET=0 RESET=1 RESET =1 RESET=1 MS71320V1 5.2 Power-on sequence Once powered, the device enters the PD mode. The content of all registers is set to its default state. One can set the device into any other operation mode by changing the configuration on the operation register. Transiting the device to RD mode and prepared for communication comprises on: • Applying appropriate configuration on registers: Operation and General • Setting en = 1 and waiting for the device to get ready and with the oscillator stable (I_osc/osc_ok) • The internal voltage regulators must be configured. It is recommended to use direct command adjust regulators to improve the system PSRR Once completed, the device is ready for communication. ST25R200 Application information DS13658 - Rev 2 page 12/88 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|