| 전자부품 데이터시트 검색엔진 |
|
LT1013AMFKB 데이터시트(PDF) 19 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
LT1013AMFKB 데이터시트(HTML) 19 Page - Texas Instruments |
|
19 / 33 page ![]() LT1013, LT1013A, LT1013D DUAL PRECISION OPERATIONAL AMPLIFIERS SLOS018H − MAY 1988 − REVISED NOVEMBER 2004 19 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 APPLICATION INFORMATION comparator applications The single-supply operation of the LT1013 is well suited for use as a precision comparator with TTL-compatible output. In systems using both operational amplifiers and comparators, the LT1013 can perform multiple duties (see Figures 25 and 26). 100 mV VCC+ = 5 V VCC− = 0 TA = 25°C Overdrive 10 mV 5 mV 2 mV 0 50 100 150 200 250 300 350 400 450 5 4 3 2 1 0 t − Time − µs Figure 25. Low-to-High-Level Output Response for Various Input Overdrives 2 mV 5 mV Overdrive 10 mV 0 50 100 150 200 250 300 350 400 450 5 4 3 2 1 0 t − Time − µs VCC+ = 5 V VCC− = 0 TA = 25°C 100 mV Figure 26. High-to-Low-Level Output Response for Various Input Overdrives low-supply operation The minimum supply voltage for proper operation of the LT1013 is 3.4 V (three NiCad batteries). Typical supply current at this voltage is 290 µA; therefore, power dissipation is only 1 mW per amplifier. offset voltage and noise testing The test circuit for measuring input offset voltage and its temperature coefficient is shown in Figure 30. This circuit, with supply voltages increased to ±20 V, also is used as the burn-in configuration. The peak-to-peak equivalent input noise voltage of the LT1013 is measured using the test circuit shown in Figure 27. The frequency response of the noise tester indicates that the 0.1-Hz corner is defined by only one zero. The test time to measure 0.1-Hz to 10-Hz noise should not exceed 10 seconds, as this time limit acts as an additional zero to eliminate noise contribution from the frequency band below 0.1 Hz. An input noise voltage test is recommended when measuring the noise of a large number of units. A 10-Hz input noise voltage measurement correlates well with a 0.1-Hz peak-to-peak noise reading because both results are determined by the white noise and the location of the 1/f corner frequency. Current noise is measured by the circuit and formula shown in Figure 28. The noise of the source resistors is subtracted. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |