27 / 36 page ![]() VIPer53 - E Transconductance error amplifier 27/36 The lowest load gives another condition for stability: The frequency FBW1 must not encounter the second order slope generated by the load pole and the integrator part of the error amplifier. This condition can be met by adjusting the CCOMP value: Equation 13 The above formula gives a minimum value for CCOMP. It can be then increased to provide a natural soft start function as this capacitor is charged by the error amplifier current capacity ICOMPhi at start-up. Figure 22. Typical compensation network C COMP R L1 C OUT ⋅ 6.3 Gm R COMP 2 ⋅⋅ ------------------------------------------------------ P OUT1 P MAX ------------------- ⋅ > P OUT1 V OUT 2 R L1 --------------- = With: 15V VDD OSC DRAIN SOURCE COMP TOVL Rcomp Ccomp 10nF |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|