| 전자부품 데이터시트 검색엔진 |
|
DDP3300A 데이터시트(PDF) 21 Page - Micronas |
|
|
|||||||||||||||||||||||||||||
DDP3300A 데이터시트(HTML) 21 Page - Micronas |
|
21 / 53 page ![]() PRELIMINARY DATA SHEET DDP 3300 A MICRONAS INTERMETALL 21 locked clock from the horizontal PLL is performed by the CCU. VSTBY VSUPD ∼50 µs normal mode standby mode Internal Reset internal oszillator CLK5 5 MHz Clock Clock Release HOUT Fig. 2–20: DDP power on, standby on/off ∼4 µs normal mode 2.4.3. DDP Standby On/Off Switching the DDP to Standby Mode is more critical be- cause of the HOUT output signal. Before the standby mode is entered, the clock source for the horizontal out- put generator has to be switched to the standby clock. Switching to Standby Mode can be done by the CCU as a reaction to a remote control command (see register 53, EHPLL + disable) or by the internal voltage supervision of the DDP. This voltage supervision activates the Power Down signal when the supply for the digital circuits (VSUPD) goes below VSUPD–pd (X4.5 V). The Power Down signal switches the clock source for the HOUT generation to the standby clock and sets the duty factor to 50%. This is exactly what the EHPLL bit does. Because the clocks from the DDP–pll and the standby clock are not in phase, the actual phase (High/Low) of the HOUT signal may be up to one pll or standby clock ( X1 µs) longer than a regular one when the clock source is changed. The voltage supervising reacts if VSUPD goes below VSUPD–pd for more than 50 ns. This Power Down signal is extended by 50 µs after VSUPD is back again. When switched off, the negative slope of the supply voltage VSUPD should not be larger than approximately 0.2 V/ µs (see Recommended Operating Conditions). RESETQ POR UPDATE 4 µs 60 µs Fig. 2–21: External RESET 2.4.4. Reset DDP Reset of most functions (exception see below) is per- formed by different sources: – power on circuit (VSTBY, VSUPD) – reset pin (DDP) voltage superv. 5 MHz clock release clock VSTBY Reset Pin voltage superv. VSUPD Reset CLK5 CLK5 observer (to HOUT gen) Fig. 2–22: DDP reset generation If one of these sources creates a reset, all the internal registers and counters are set to zero. When this reset source becomes inactive, the internal reset is still active for 4 µs. After that time all the internal registers are loaded with the values defined in the defaults ROM. All the registers which are updated with the vertical sync (chain registers) get these values with the next vertical sync. During this initialization procedure (approx. 60 µs) it is not possible to access the DDP via the I2C-bus. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |