33 / 50 page ![]() SRIX4K SRIX4K commands 33/50 9.5 COMPLETION() command Command Code = 0Fh On receiving the COMPLETION() command, a SRIX4K in SELECTED state switches to DEACTIVATED state and stops decoding any new commands. The SRIX4K is then locked in this state until a complete reset (tag out of the field range). A new SRIX4K can thus be accessed through a SELECT() command without having to remove the previous one from the field. The COMPLETION() command does not generate a response. All SRIX4K devices not in SELECTED state ignore the COMPLETION() command. Figure 35. COMPLETION request format Request parameters: – No parameter Figure 36. COMPLETION response format Figure 37. COMPLETION frame exchange between Reader and SRIX4K SOF COMPLETION CRCL CRCH EOF AI07679 0Fh 8 bits 8 bits AI07680 No Response SOF 0Fh CRCL CRCH EOF AI07681 Reader SRIX4K No Response |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|