| 전자부품 데이터시트 검색엔진 |
|
MPC8280 데이터시트(PDF) 981 Page - Freescale Semiconductor, Inc |
|
|
|||||||||||||||||||||||||||||
MPC8280 데이터시트(HTML) 981 Page - Freescale Semiconductor, Inc |
|
981 / 1386 page ![]() ATM Controller and AAL0, AAL1, and AAL5 MPC8280 PowerQUICC II Family Reference Manual, Rev. 1 Freescale Semiconductor 31-21 6. When B-RM is received with CI=0 and NI=0 (no increase), ACR is increased by RIF × PCR (rate increase factor). The new ACR is determined first by letting ACRtemp be the min of (ACR, ER), and then taking the max of (ACRtemp, MCR). 7. Before sending an F-RM cell, if more than ADTF (ACR decrease time factor) has elapsed since sending the last F-RM cell, ACR is reduced to ICR. In other words, if the source does not fully use its gained bandwidth, it loses it and resumes sending at its initial cell rate. 8. Before sending an F-RM cell and after action 7, if more than Crm F-RM cells were sent since the last B-RM cell was received with BN=0 (backward notification), the ACR is reduced by ACR × CDF (cutoff decrease factor). 9. A source whose ACR is less than the tag cell rate (TCR) sends out-of-rate cells at the TCR. This behavior is intended for sources whose rates were set to zero by the network. These sources should periodically sense the network state by sending out-of-rate RM cells. In this case data cells will not be sent. 10. An RM cell with an incorrect CRC10 is discarded and the UNI statistics tables are updated. 31.5.1.2 ABR Flow Control Destination End-System Behavior The MPC8280’s implementation of ABR flow control for end-system destinations is described in the following steps: 1. A received F-RM cell is turned around and sent as a B-RM cells. 2. The DIR field of the received F-RM cell is changed from 0 to 1 (backward DIR). 3. The CCR and MCR fields are taken from the F-RM and is not changed. 4. The CI bit of the B-RM cell is set if the previous data cell arrived with EFCI = 1 (congestion bit in the ATM cell header). 5. The ER field of the turn around B-RM cells is limited by TCTE[ER-BRM]. 6. If a F-RM cell arrives before the previous F-RM cell was turned around (for the same connection), the new RM cell overwrites the old RM cell. 31.5.1.3 ABR Flowcharts The MPC8280’s ABR transmit and receive flow control is described in the following flowcharts. See Figure 31-11, Figure 31-12, Figure 31-13, and Figure 31-14. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |