| 전자부품 데이터시트 검색엔진 |
|
PS02 데이터시트(PDF) 4 Page - Same Sky Devices |
|
|
|||||||||||||||||||||||||||||
PS02 데이터시트(HTML) 4 Page - Same Sky Devices |
|
4 / 7 page ![]() SAME SKY | SERIES: PS02 | DESCRIPTION: PRESSURE SENSOR date 09/12/2024 | page 4 of 7 sameskydevices.com I2C OPERATION S P A N from master to slave from slave to master START condition STOP condition acknowledge not acknowledge SP AA SlaveAddr 0 Command write Convert Pressure Value Pressure (kPa) = P max/0.8*(x/2 23 -0.1) Read Data P N A SA A SlaveAddr 1 Measurement <23:16> read Measurement <15:8> Measurement <7:0> Command Request I2C slave address: Ox06D Pressure Command: 0x06 Temperature Command: 0x09 Convert Temperature Value For x<223: Temperature (⁰C) = x/216+25 For x ≥223: Temperature (⁰C) = (x-224)/216+25 Steps to read data from PS02 sensor 1. Write the corresponding command to the sensor (0x06 for pressure, 0x09 for temperature). 2. Read three bytes from the sensor. 3. Combine these three bytes into a single 24-bit value. 4. Convert the 24-bit value to a standard pressure or temperature unit using the formulas below. Additional Resources: Product Page | 3D Model |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|