| 전자부품 데이터시트 검색엔진 |
|
20D301K 데이터시트(PDF) 14 Page - TYEE Products Inc |
|
|
|||||||||||||||||||||||||||||
20D301K 데이터시트(HTML) 14 Page - TYEE Products Inc |
|
14 / 15 page ![]() (Electrical) 05D180K to 05D680K 0.45A (2 ms) 05D820K to 05D471K 14A (8/20μs) 07D180K to 07D680K 12A (8/20μs) 07D820K to 07D471K 35A (8/20μs) 10D180K to 10D680K 35A (8/20μs) 10D820K to 10D471K 70A (8/20μs) 14D180K to 14D680K 45A (8/20μs) 14D820K to 14D471K 90A (8/20μs) 20D180K to 20D680K 55A (8/20μs) 20D820K to 20D471K 100A (8/20μs) (Mechanical) Approximately 95% of the terminals shall be covered with solder uni-formly Resistance to Soldering Heat After each lead shall be dipped into a solder bath having a temperature 260±5℃ (3 series: 250±5℃) to a point 2.0 to 2.5 mm from the body of the unit, using shieldig board (t=1.5mm), be held there for specified time (3series: 3±1 s, 5 series: 5±1 s and others: 10±1 s ), and then be stored at room temperature and humidity for 1 to 2 hours. The change of Vc and mechanical damages are examined. △VcmA/VcmA≦±5% No outstanding damage Vibration After repeadly applying a single harmonic vibration (amplitude: 0.75 mm) double amplitude:1.5mm with 1 minute vibration frequency cycles (10 Hz to 55 Hz to 10 Hz) to each of three perpendicular directions for 2 hours. Thereafter, the unit shall be visually examined. Solderadilty After dipping the terminals to a depth of approximately 3mm from the body in a soldering bath of 235±5℃ for 2±0.5 seconds, the terminal shall be visually examined. Robustness of Terminations (Bending) The unit shall be secured with its terminal kept vertical and the force specified below be applied in the axial direction. The terminal shall gradually be bent by 90° in one direction, then 90°in the opposite direction, and again back to the original position. The damage of the terminal shall be visually examined. Terminal diameter Force Ø 0.6 mm 4.9 N (0.5Kgf) Ø 0.8 mm 4.9 N (0.5Kgf) Ø 1.0 mm 9.8 N (1.0Kgf) Characteristics Test Methods Specifications Robustness of Terminations (Tensile) After gradually applying the force specified below and keeping the unit fixed for the seconds, the terminal shall be visually examined for any damage. No outstanding damage Terminal diameter Force Ø 0.6 mm 9.8 N (1.0Kgf) Ø 0.8 mm 9.8 N (1.0Kgf) Ø 1.0 mm 19.6 N (2.0Kgf) 20 Series Note: Varistor voltage change of forward direction shall be measured in the test of uni-pole surge life and DC load life 10 Series 14 Series Characteristics Test Methods Specifications Impulse Life(II) The change of Vc shall be measured after the impulse listed below is applied 100000 times continuously with the interval of ten seconds at room temperature . △VcmA/VcmA≦±10% 5 Series 7 Series TYEE Products Inc. http://www.tyeeusa.com/ Page:14/15 |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |