9 / 16 page ![]() Data Sheet Rev. G, November 2023 | Subject to change without notice 9 of 16 www.qorvo.com © 2023 Qorvo US, Inc. All rights reserved. ACT4529 40 V/3.0 A CV/CC Buck Converter Featuring QC2.0, USB Auto-Detect and USB-PD ® APPLICATIONS INFORMATION Current Sense Resistor The traces leading to and from the sense resistor can be significant error sources. With small value sense resistors, trace resistance shared with the load can cause significant errors. It is recommended to connect the sense resistor pads directly to the CSP and CSN pins using “Kelvin” or “4-wire” connection techniques as shown below. Current Limit Setting If output current hits current limit, output voltage drops to keep the current to a constant value. The following equation calculates the constant current limit. ������������������������������������������������������������������������(������������)= 66������������������������ ������������������������������������(������������������������) (6) Where Rcs is current sense resistor. PCB Load Trace Kevin Sense Traces Sense Resistor |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|