| 전자부품 데이터시트 검색엔진 |
|
L6740L 데이터시트(PDF) 31 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L6740L 데이터시트(HTML) 31 Page - STMicroelectronics |
|
31 / 44 page ![]() L6740L Output voltage monitoring and protections 31/44 7 Output voltage monitoring and protections L6740L monitors the regulated voltage of both sections through pin VSEN and NB_VSEN in order to manage OV, UV and PWRGOOD. The device shows different thresholds when in different operative conditions but the behavior in response to a protection event is still the same as described below. Protections are active also during soft-start (See Section 6.10) while they are masked dur- ing OTF-VID transitions with an additional delay to avoid false triggering. Table 12. L6740L protection at a glance. 7.1 Programmable over voltage Once VCC crosses the turn-ON threshold and the device is enabled (EN = 1), L6740L pro- vides an Over Voltage Protection for both the sections: when the voltage sensed by VSEN and/or NB_VSEN overcomes the OV threshold, the controller: – Permanently sets the PWM of the involved section to zero keeping ENDRV of that section high in order to keep all the Low-Side MOSFETs on to protect the load of the Section in OV condition. Protection Section CORE NORTH BRIDGE Over voltage (OV) SVI / PVI: Programmable threshold according to OVP pin. V_FIX: Fixed to 1.8V; OVP pin is externally shorted to SGND. Action: PWMx = 0 & ENDRVx = 1; Other Section (SVI only): PWMx = HiZ; ENDRVx = 0; FLT driven High. Under voltage (UV) VSEN, NB_VSEN = VID -400mV. Active after Ref > 500mV Action: All PWMx = HiZ; ENDRVx = 0; FLT Driven High. PWRGOOD PWRGOOD is the logic AND between internal CORE and NB PGOOD in SVI mode while is the CORE section PGOOD in PVI mode. Each PGOOD is set to zero when the related voltage falls below the programmed reference -250mV. Action: Section(s) continue switching, PWRGOOD driven low. VSEN, NB_VSEN Disconnection Set when VSEN > CS1- +600mV. Action: UV-Like 30 µA Pull-Up from NB_VSEN to set OV (SVI Only). Action: OV-Like FBG, NB_FBG Disconnection Internal Comparator across the opamp to recover from GND losses. Action: UV-Like Over current (OC) Current Monitor across Inductor DCR. Dual Protection, per-phase and average. Action: UV-Like Current Monitor across LS RdsON. Constant Current, Valley CLimit. Action: UV-Like On-The-Fly VID Masked with the exception of OC with additional 16 clock delay to prevent from false triggering (both SVI and PVI). |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |