13 / 58 page ![]() Bosch Sensortec | BMP384 Datasheet 13 | 58 Modifications reserved |Data subject not change without notice | Printed in Germany Document number: BST-BMP384-DS003-11 Revision_1.0_112020 3.4.1. Pressure measurement Pressure measurement can be enabled or skipped. Skipping the measurement could be useful if BMP384 is used as temperature sensor. When enabled, several oversampling options exist. Each oversampling step reduces noise and increases the output resolution by one bit, which is stored in the XLSB data register. Enabling the measurement is selected by press_en bit in “PW_CTRL[0]” register (see 4.3.16). The oversampling setting osr_p can be configured in “OSR[2:0]” register (see 4.3.17). Table 6: osr_p settings Oversampling setting osr_p Pressure oversampling Typical pressure resolution Recommended temperature oversampling Ultra low power 000 ×1 16 bit / 2.64 Pa ×1 Low power 001 ×2 17 bit / 1.32 Pa ×1 Standard resolution 010 ×4 18 bit / 0.66 Pa ×1 High resolution 011 ×8 19 bit / 0.33 Pa ×1 Ultra high resolution 100 ×16 20 bit / 0.17 Pa ×2 Highest resolution 101 ×32 21 bit / 0.085 Pa ×2 3.4.2. Temperature measurement Temperature measurement can be enabled or skipped. Skipping the measurement could be useful to measure pressure extremely rapidly. When enabled, several oversampling options exist. Each oversampling step reduces noise and increases the output resolution by one bit, which is stored in the XLSB data register. Noise and increases the output resolution by one bit, which is stored in the XLSB data register. Enabling the measurement is selected by temp_en bit in “PW_CTRL[1]” register (see 4.3.16). The oversampling setting osr_t can be configured in “OSR[5:3]” register (see 4.3.17). Table 7: osrs_t settings osr_t Temperature oversampling Typical temperature resolution 000 ×1 16 bit / 0.0050 °C 001 ×2 17 bit / 0.0025 °C 010 ×4 18 bit / 0.0012 °C 011 ×8 19 bit / 0.0006 °C 100 ×16 20 bit / 0.0003 °C 101 ×32 21 bit / 0.00015 °C It is recommended to base the value of osr_t on the selected value of osrs_p as per Table 6 . Temperature oversampling above ×2 is possible, but will not significantly improve the accuracy of the pressure output any further. The reason for this is that the noise of the compensated pressure value depends more on the raw pressure than on the raw temperature noise. Following the recommended setting will result in an optimal noise-to-power ratio. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |