| 전자부품 데이터시트 검색엔진 |
|
BME280 데이터시트(PDF) 49 Page - Bosch Sensortec GmbH |
|
|
|||||||||||||||||||||||||||||
BME280 데이터시트(HTML) 49 Page - Bosch Sensortec GmbH |
|
49 / 60 page ![]() Bosch Sensortec | BME280 Data sheet 49 | 60 Modifications reserved | Data subject to change without notice Document number: BST-BME280-DS001-23 Revision_1.23_012022 8. Appendix A: Alternative compensation formulas 8.1 Compensation formulas in double precision floating point Please note that it is strongly advised to use the API available from Bosch Sensortec to perform readout and compensation. If this is not wanted, the code below can be applied at the user’s risk. Both pressure and temperature values are expected to be received in 20 bit format, positive, stored in a 32 bit signed integer. Humidity is expected to be received in 16 bit format, positive, stored in a 32 bit signed integer. The variable t_fine (signed 32 bit) carries a fine resolution temperature value over to the pressure compensation formula and could be implemented as a global variable. The data type “BME280_S32_t” should define a 32 bit signed integer variable type and could usually be defined as “long signed int”. The revision of the code is rev. 1.1 (pressure and temperature) and rev. 1.0 (humidity). Compensating the measurement value with double precision gives the best possible accuracy but is only recommended for PC applications. // Returns temperature in DegC, double precision. Output value of “51.23” equals 51.23 DegC. // t_fine carries fine temperature as global value BME280_S32_t t_fine; double BME280_compensate_T_double(BME280_S32_t adc_T) { double var1, var2, T; var1 = (((double)adc_T)/16384.0 – ((double)dig_T1)/1024.0) * ((double)dig_T2); var2 = ((((double)adc_T)/131072.0 – ((double)dig_T1)/8192.0) * (((double)adc_T)/131072.0 – ((double) dig_T1)/8192.0)) * ((double)dig_T3); t_fine = (BME280_S32_t)(var1 + var2); T = (var1 + var2) / 5120.0; return T; } // Returns pressure in Pa as double. Output value of “96386.2” equals 96386.2 Pa = 963.862 hPa double BME280_compensate_P_double(BME280_S32_t adc_P) { double var1, var2, p; var1 = ((double)t_fine/2.0) – 64000.0; var2 = var1 * var1 * ((double)dig_P6) / 32768.0; var2 = var2 + var1 * ((double)dig_P5) * 2.0; var2 = (var2/4.0)+(((double)dig_P4) * 65536.0); var1 = (((double)dig_P3) * var1 * var1 / 524288.0 + ((double)dig_P2) * var1) / 524288.0; var1 = (1.0 + var1 / 32768.0)*((double)dig_P1); if (var1 == 0.0) { return 0; // avoid exception caused by division by zero } p = 1048576.0 – (double)adc_P; p = (p – (var2 / 4096.0)) * 6250.0 / var1; var1 = ((double)dig_P9) * p * p / 2147483648.0; var2 = p * ((double)dig_P8) / 32768.0; p = p + (var1 + var2 + ((double)dig_P7)) / 16.0; return p; } // Returns humidity in %rH as as double. Output value of “46.332” represents 46.332 %rH double bme280_compensate_H_double(BME280_S32_t adc_H); { double var_H; var_H = (((double)t_fine) – 76800.0); var_H = (adc_H – (((double)dig_H4) * 64.0 + ((double)dig_H5) / 16384.0 * var_H)) * (((double)dig_H2) / 65536.0 * (1.0 + ((double)dig_H6) / 67108864.0 * var_H * (1.0 + ((double)dig_H3) / 67108864.0 * var_H))); var_H = var_H * (1.0 – ((double)dig_H1) * var_H / 524288.0); if (var_H > 100.0) var_H = 100.0; else if (var_H < 0.0) var_H = 0.0; return var_H; } |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |