Back Button ADE9178GTL+T Datasheet HTML 47Page - Analog Devices ADE9178GTL+T Datasheet HTML 48Page - Analog Devices ADE9178GTL+T Datasheet HTML 49Page - Analog Devices ADE9178GTL+T Datasheet HTML 50Page - Analog Devices ADE9178GTL+T Datasheet HTML 51Page - Analog Devices ADE9178GTL+T Datasheet HTML 52Page - Analog Devices ADE9178GTL+T Datasheet HTML 53Page - Analog Devices ADE9178GTL+T Datasheet HTML 54Page - Analog Devices ADE9178GTL+T Datasheet HTML 55Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 51 / 122 page
background image
Data Sheet
ADE9178
THEORY OF OPERATION
analog.com
Rev. A | 51 of 122
Table 27. ERROR_STATUS Register Table
ERROR_STATUS Bit
Description
Possible Cause of Issue
How to Debug during
Development
How to Handle in the Field
ADC_INIT_ERROR[0]
Error occurred in ADC
initialization.
1. ADC SPI signal integrity
issue.
2. Error in ADCs.
1. Check signal integrity of
SPI connections between the
ADE9178 and ADCs.
2. See the Quick Start section
and ensure that ADC related
parameters are configured
properly.
3. Read STATUS registers of
ADCs to check if any error bits
are set.
4. Reset the ADE9178 and
ADCs. Initialize ADCs using
ADC_INIT of ADC_CONTROL
register after ADE9178 reset.
1. Read STATUS registers of
ADCs to check if any error bits
are set.
2. Reset the ADE9178 and
ADCs. Initialize ADCs using
ADC_INIT of ADC_CONTROL
register after ADE9178 reset.
ERROR0[1]
Internal Error Occurred.
Reset the ADE9178 and ADCs.
Initialize ADCs using ADC_INIT
of ADC_CONTROL register after
ADE9178 reset.
Reset the ADE9178 and ADCs.
Initialize ADCs using ADC_INIT
of ADC_CONTROL register after
ADE9178 reset.
ERROR1[2]
Internal Error Occurred.
Reset the ADE9178 and ADCs.
Initialize ADCs using ADC_INIT
of ADC_CONTROL register after
ADE9178 reset.
Reset the ADE9178 and ADCs.
Initialize ADCs using ADC_INIT
of ADC_CONTROL register after
ADE9178 reset.
ERROR2[3]
Internal Error Occurred.
Reset the ADE9178 and ADCs.
Initialize ADCs using ADC_INIT
of ADC_CONTROL register after
ADE9178 reset.
Reset the ADE9178 and ADCs.
Initialize ADCs using ADC_INIT
of ADC_CONTROL register after
ADE9178 reset.
ERROR3[4]
Internal Error Occurred.
Reset the ADE9178 and ADCs.
Initialize ADCs using ADC_INIT
of ADC_CONTROL register after
ADE9178 reset.
Reset the ADE9178 and ADCs.
Initialize ADCs using ADC_INIT
of ADC_CONTROL register after
ADE9178 reset.
ERROR4[5]
Internal Error Occurred.
Reset the ADE9178 and ADCs.
Initialize ADCs using ADC_INIT
of ADC_CONTROL register after
ADE9178 reset.
Reset the ADE9178 and ADCs.
Initialize ADCs using ADC_INIT
of ADC_CONTROL register after
ADE9178 reset.
ADC_CRC_ERROR[6]
ADC SPI CRC Error Occurs.
ADC SPI CRC errors are
detected on the samples read
from the ADCs.
1. Check signal integrity of
SPI connections between the
ADE9178 and ADCs.
2. Ensure that the ADC related
registers are configured correctly
as per the Quick Start section.
3. Read STATUS registers of
ADCs to check if any error bits
are set.
4. If error persists, reset
the ADE9178 and ADCs and
perform ADC initialization again.
If CRC error occurs, the
ADE9178 automatically discards
the ADC samples, and previous
good samples are used for
measurements.
ERROR5[7]
Internal Error Occurred.
Reset the ADE9178 and ADCs.
Initialize ADCs using ADC_INIT
of ADC_CONTROL register after
ADE9178 reset.
Reset the ADE9178 and ADCs.
Initialize ADCs using ADC_INIT
of ADC_CONTROL register after
ADE9178 reset.
DREADY_FREQ_ERROR[8]
ADC Data Ready Frequency
Error. This bit is set when ADC
Data Ready frequency is not 4
ADC DREADY frequency might
be configured wrong. ADCs
reset while ADC is running.
1. Check signal integrity of the
DREADY signal.
2. Reset the ADE9178 and
ADCs. Initialize ADCs using
Clear DREADY_FREQ_ERR bit
by writing 1 to bit 8 of ER-
ROR_STATUS register. If the bit
re-asserts reset the ADE9178



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com