| 전자부품 데이터시트 검색엔진 |
|
P1-25/I2/SVB 데이터시트(PDF) 3 Page - Eaton All Rights Reserved. |
|
|
|||||||||||||||||||||||||||||
P1-25/I2/SVB 데이터시트(HTML) 3 Page - Eaton All Rights Reserved. |
|
3 / 6 page ![]() 12/21/2015 207293 - HPL-ED2015 V18.0 EN 3 / 6 230 V P kW 5.5 400 V 415 V P kW 11 500 V P kW 11 690 V P kW 11 Rated operational current motor load switch 230 V Ie A 25 400 V 415 V Ie A 25 500 V Ie A 17.4 690 V Ie A 12.6 DC DC-1, Load-break switches L/R = 1 ms Rated operational current Ie A 25 Voltage per contact pair in series V 60 DC-23A, motor load switch L/R = 15 ms 24 V Rated operational current Ie A 25 Contacts Quantity 1 48 V Rated operational current Ie A 25 Contacts Quantity 2 60 V Rated operational current Ie A 25 Contacts Quantity 2 120 V Rated operational current Ie A 12 Contacts Quantity 3 Control circuit reliability at 24 V DC, 10 mA Fault probability HF < 10 -5, < 1 fault in 100000 operations Terminalcapacities Solid or stranded mm2 1 x (1,5 - 6) 2 x (1,5 - 6) Flexible with ferrules to DIN 46228 mm2 1 x (1 - 4) 2 x (1 - 4) Terminal screw M4 Max. tightening torque Nm 1.6 Technicalsafetyparameters: Notes B10d values as per EN ISO 13849-1, table C1 DesignverificationasperIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation In A 25 Heat dissipation per pole, current-dependent Pvid W 1.1 Equipment heat dissipation, current-dependent Pvid W 0 Static heat dissipation, non-current-dependent Pvs W 0 Heat dissipation capacity Pdiss W 0 Operating ambient temperature min. °C -25 Operating ambient temperature max. °C 40 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Please enquire 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |