| 전자부품 데이터시트 검색엔진 |
|
TZ4M-R2S 데이터시트(PDF) 12 Page - Autonics Corporation |
|
|
|||||||||||||||||||||||||||||
TZ4M-R2S 데이터시트(HTML) 12 Page - Autonics Corporation |
|
12 / 16 page ![]() H-83 (A) Photo electric sensor (B) Fiber optic sensor (C) Door/Area sensor (D) Proximity sensor (E) Pressure sensor (F) Rotary encoder (G) Connector/ Socket (H) Temp. controller (I) SSR/ Power controller (J) Counter (K) Timer (L) Panel meter (M) Tacho/ Speed/ Pulse meter (N) Display unit (O) Sensor controller (P) Switching mode power supply (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel (S) Field network device (T) Software (U) Other Dual PID Auto Tuning Control Setting value (SV) Decrease reset Increase reset Normal deviation Normal deviation Process value(PV) (Fig. 1) SV S PV t PIdF ※ t : Reaching time S : Overshoot SV: Setting value PV: Process value (Fig. 2) SV PV t PIdS ※ t : Reaching time SV: Setting value PV: Process value ON/OFF control Manual reset [ REST] Dual PID control RS485 communication Decimal point setting [ DOT] ON/OFF control is called two position control because the output turns on when PV falls lower than SV and the output turns off when PV is higher than SV. This control method is not only for controlling temperature, but also it is basic control method for sequence control. ● If you set value P as )0 in parameter 1 group, ON/OFF control will operate. ● There is a programmable temperature difference between ON and OFF in ON/OFF control, if difference is too small, then hunting(chattering) can occur. ● Temperature difference can be set in HYS mode of parameter 1 group. Setting range is 1 to 100(or 0.1 to 100.0). ● HYS mode is displayed when P value is )0, but HYS will not be displayed, and then jump if P value is not )0. ● This ON/OFF control should not be applied when equipment(cooling compressor) to be controlled can be damaged by frequent ON and OFF. ● Even if ON/OFF control is stable status, the hunting can be occurred by setting value in HYS or capacity of the heater or response characteristic of the equipment to be controlled or installing position of the sensor. Please consider above points to minimize the hunting when designing the system. Proportional control has deviation because rising time is not same as falling time, even if the unit operates normally. Manual reset function is used at proportional control mode only. ● If set RESTfunction in parameter 1 group, the manual reset will run. ● When PV and SV is equal, REST value is 50.0% and when control is stable, if the temperature is lower than SV, RESTvalue should be higher and on the other hand, REST value should be smaller. ● REST setting method according to result of control. When controlling temperature, two types of control characteristic are available as below. One is when you need to minimize the time which PV reaches to SV as like(Fig. 1). The other is when you need to minimize overshoot even though the reaching time(PV to SV) is slow(Fig. 2). ● There are high-speed response type and low-speed response type built in this unit. Therefore user can select each function according to their application. ● You can select dual PID control function in parameter 2 group. It is selectable PIdFor PIdS in PIDT mode. PIdF (high-speed response type) This mode is applied to machines or systems which require high-speed response. PIdS (low-speed response type) It is PID Slow, used to minimize overshoot even though the response is slow. For control temperature of oil, plating machine have a possibility of fire with overshoot, PIdS (limit over) should be used. ※Factory default setting is PIdS. Please select mode according to control system. It is used on the purpose that transmitting PV to an external equipment, setting SV at the external equipment. ● It can be set at BPS, ADRS in second parameter 2 group. ● Communication speed[ BPS] set range: 2400, 4800, 9600bps ● Start bit(1bit, fixed), Stop bit(1bit, fixed), Parity bit(none) ● Communication address[ ADRS] set range: 1 to 99 Communication converters (sold separately) SCM-38I(RS-232C to RS485 converter) SCM-US48I(USB to RS485 converter) SCM-WF48(Wi-Fi to RS485/USB communication converter(available soon) Decimal point is displayed as DOT in parameter 2 group when the input is analog only.(0-10VDC, 1-5VDC, DC4-20mA) |
|
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |