전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

TMP104 데이터시트(PDF) 13 Page - Texas Instruments

부품명 TMP104
상세설명  TMP104 Low-Power, Digital Temperature Sensor With SMAART Wire™ Interface
PDF  23 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  TI2 [Texas Instruments]
홈페이지  https://www.ti.com
Logo TI2 - Texas Instruments

TMP104 데이터시트(HTML) 13 Page - Texas Instruments

Back Button TMP104 Datasheet HTML 9Page - Texas Instruments TMP104 Datasheet HTML 10Page - Texas Instruments TMP104 Datasheet HTML 11Page - Texas Instruments TMP104 Datasheet HTML 12Page - Texas Instruments TMP104 Datasheet HTML 13Page - Texas Instruments TMP104 Datasheet HTML 14Page - Texas Instruments TMP104 Datasheet HTML 15Page - Texas Instruments TMP104 Datasheet HTML 16Page - Texas Instruments TMP104 Datasheet HTML 17Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 23 page
background image
Measured
Temperature
T
HIGH
T
LOW
FH Bit
(
Transparent Mode)
Read of Configuration Register
Time
FL Bit
(
Transparent Mode)
FH Bit
(Latch Mode)
FL Bit
(Latch Mode)
13
TMP104
www.ti.com
SBOS564B – NOVEMBER 2011 – REVISED DECEMBER 2018
Product Folder Links: TMP104
Submit Documentation Feedback
Copyright © 2011–2018, Texas Instruments Incorporated
Figure 13. Temperature Flag Functional Diagram
The latch bit (LC) in the Configuration Register is used to latch the value of the flag bits (FH and FL) until the
master issues a read command to the Configuration Register. The flag bits are set to '0' if a read command is
received by the TMP104, or if LC = 0 and the temperature is within the temperature limits. The power-on default
values for these bits are FH = 0, FL = 0, and LC = 0.
7.4.2.2 Conversion Rate (CR1, CR0)
The conversion rate bits (CR1 and CR0), located in the Configuration Register, configure the TMP104 for
conversion rates of 8 Hz, 4 Hz, 1 Hz, or 0.25 Hz (default). The TMP104 has a typical conversion time of 26 ms.
To achieve different conversion rates, the TMP104 performs a single conversion and then powers down and
waits for the appropriate delay set by CR1 and CR0. Table 8 shows the settings for CR1 and CR0.
Table 8. Conversion Rate Settings
CR1
CR0
CONVERSION RATE
0
0
0.25 Hz (default)
0
1
1 Hz
1
0
4 Hz
1
1
8 Hz



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com