Back Button ISO7641FCDWR Datasheet HTML 18Page - Texas Instruments ISO7641FCDWR Datasheet HTML 19Page - Texas Instruments ISO7641FCDWR Datasheet HTML 20Page - Texas Instruments ISO7641FCDWR Datasheet HTML 21Page - Texas Instruments ISO7641FCDWR Datasheet HTML 22Page - Texas Instruments ISO7641FCDWR Datasheet HTML 23Page - Texas Instruments ISO7641FCDWR Datasheet HTML 24Page - Texas Instruments ISO7641FCDWR Datasheet HTML 25Page - Texas Instruments ISO7641FCDWR Datasheet HTML 26Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 22 / 37 page
background image
Ambient Temperature - (qC)
0
50
100
150
200
0
100
200
300
400
500
600
700
D001
D001
VCC1 = VCC2 = 2.7 V
VCC1 = VCC2 = 3.6 V
VCC1 = VCC2 = 5.5 V
22
ISO7631FM, ISO7631FC, ISO7641FC
SLLSEC3F – SEPTEMBER 2012 – REVISED APRIL 2016
www.ti.com
Product Folder Links: ISO7631FM ISO7631FC ISO7641FC
Submit Documentation Feedback
Copyright © 2012–2016, Texas Instruments Incorporated
9.3.1.1 Safety Limiting Values
Safety limiting intends to prevent potential damage to the isolation barrier upon failure of input or output circuitry.
A failure of the IO can allow low resistance to ground or the supply and, without current limiting, dissipate
sufficient power to overheat the die and damage the isolation barrier potentially leading to secondary system
failures.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
IS
Safety input, output, or supply
current
DW-16
θJA = 77.5 °C/W, VI = 5.5V, TJ = 150°C, TA = 25°C
293
mA
θJA = 77.5 °C/W, VI = 3.6V, TJ = 150°C, TA = 25°C
448
θJA = 77.5 °C/W, VI = 2.7V, TJ = 150°C, TA = 25°C
597
TS
Maximum safety temperature
150
°C
The safety-limiting constraint is the absolute maximum junction temperature specified in the absolute maximum
ratings table. The power dissipation and junction-to-air thermal impedance of the device installed in the
application hardware determines the junction temperature. The assumed junction-to-air thermal resistance in the
Thermal Information table is that of a device installed on a High-K Test Board for Leaded Surface Mount
Packages. The power is the recommended maximum input voltage times the current. The junction temperature is
then the ambient temperature plus the power times the junction-to-air thermal resistance.
Figure 22. Thermal Derating Curve for Safety Limiting Current per VDE



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com