| 전자부품 데이터시트 검색엔진 |
|
INA253A2IPWR 데이터시트(PDF) 23 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
INA253A2IPWR 데이터시트(HTML) 23 Page - Texas Instruments |
|
23 / 36 page ![]() INA253 REF2 VS OUT GND IN+ IN± ± REF1 2.7-V to 5.5-V VDD 23 INA253 www.ti.com SLOS954A – JULY 2018 – REVISED DECEMBER 2018 Product Folder Links: INA253 Submit Documentation Feedback Copyright © 2018, Texas Instruments Incorporated 9.2.2 Speaker Enhancements and Diagnostics Using Current Sense Amplifier CLASS-D audio amplifiers in conjunction with the INA253 provide accurate speaker load current. Speaker load current is used to determine speaker diagnostics, and can further be expanded to measure key speaker parameters, such as speaker coil resistance and speaker real-time ambient temperature. Figure 43. Current Sensing in a CLASS-D Subsystem 9.2.2.1 Design Requirements Table 3. Design Parameters DESIGN PARAMETER EXAMPLE VALUE Common-mode voltage 24 V Power-supply voltage 5 V Maximum rms current 5 A Frequency sweep 20 Hz to 20 Khz 9.2.2.2 Detailed Design Procedure For this application, the INA253 measures current flowing through the speaker from the CLASS-D amplifier. The integrated shunt of 2 mΩ with an inductance of only 3 nH is an excellent choice for current sensing in speaker applications where low inductance is required. The low-inductive shunt enables accurate current sensing across frequencies over the audio range of 20 hz to 20 kHz. The INA253 is setup in a bidirectional with the reference set to mid-supply as shown in Figure 37. The power supply to INA253 is setup at 5 V. The output of INA253 is set at 2.5 V. The INA253 with a gain of 100 mV/A, the INA253 output for a peak to peak of 10-A current the output of the INA253 will swing from 3.5 V to 1.5 V. The output can be directly connected to ADC input that has a full scale range of 5 V. The INA253 has a low THD+N of 0.1% at 1 kHz that enables distortion measurement of speaker. The INA253 can measure the impedance of the speaker and accurately measure the resonance frequency and peak impedance at resonance frequency. The INA253 can accurately track changes in impedance real time. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |