13 / 32 page ![]() 13 13 COUNTER B OPERATING MODE Select the operating mode for Counter B. SELECTION MODE DESCRIPTION Does not count. Count X1 Adds Input B falling edge. Count X1 w/direction Adds Input B falling edge if User 2 is high. Subtracts Input B falling edge if User 2 is low. Quad X1 Adds Input B rising edge when User 2 is high. Subtracts Input B falling edge when User 2 is high. Quad X2 Adds Input B rising edge when User 2 is high and Input B falling edge when User 2 is low. Subtracts Input B falling edge when User 2 is high and Input B rising edge when User 2 is low. Count X2 Adds Input B rising and falling edges. Count X2 w/direction Adds Input B rising and falling edges if User 2 is high. Subtracts Input B rising and falling edge if User 2 is low. COUNTER B RESET ACTION When Counter B is reset, it returns to zero or Counter B count load value. This reset action affects all Counter B resets, except the Setpoint Counter Auto Reset Action in Module 6. COUNTER B DECIMAL POSITION This selects the decimal point position for Counter B and any setpoint value assigned to Counter B. The selection will also affect Counter B scale factor calculations. COUNTER B SCALE FACTOR The number of input counts is multiplied by the scale factor and the scale multiplier to obtain the desired process value. A scale factor of 1.00000 will result in the display of the actual number of input counts. (Details on scaling calculations are explained at the end of this section.) to COUNTER B SCALE MULTIPLIER The number of input counts is multiplied by the scale multiplier and the scale factor to obtain the desired process value. A scale multiplier of 1 will result in only the scale factor affecting the display. (Details on scaling calculations are explained at the end of this section.) COUNTER B COUNT LOAD VALUE When reset to count load action is selected, Counter B will reset to this value. to SCALING CALCULATIONS Each counter has the ability to scale an input signal to a desired display value. This is accomplished by the counter mode (x-), scale factor (x), scale multiplier (x) and decimal point (x). The scale factor is calculated using: SF (x) = Desired Display Decimal DDD (Number of pulses per ‘single’ unit x CM x SM) Where: Desired Display Decimal DDD x Counter Decimal Selection 1 0 None 10 0.0 Tenths 100 0.00 Hundredths 1000 0.000 Thousandths 10000 0.0000 Ten Thousandths 100000 0.00000 Hundred Thousandths Number of pulses per ‘single’ unit: pulses per unit generated by the process (i.e. # of pulses per foot) CM: Counter Mode(x-) times factor of the mode 1,2 or 4. SM: Scale Multiplier (x) selection of 1, 0.1 or 0.01. Example: 1. Show feet to the hundredths (0.00) with 100 pulses per foot: Scale Factor would be 100 / (100 x 1 x 1) = 1 (In this case, the scale multiplier and counter mode factor are 1) 2. Show feet with 120 pulses per foot: Scale Factor would be 1 / (120 x 1 x 1) = 0.0083333. (In this case, the scale multiplier of 0.01 could be used: 1 / (120 x 1 x 0.01) = 0.83333 or show to hundredths (0.00): 100 / (120 x 1 x 1) = 0.8333.) General Rules on Scaling 1. It is recommended that, the scale factor be as close as possible to, but not exceeding 1.00000. This can be accomplished by increasing or decreasing the counter decimal point position, using the scale multiplier, or selecting a different count mode. 2. To double the number of pulses per unit, use counter modes direction X2 or quad X2. To increase it by four times, use counter mode quad X4. Using these modes will decrease the maximum input frequency. 3. A scale factor greater than 1.00000 will cause Counter display rounding. In this case, digit jumps could be caused by the internal count register rounding the display. The precision of a counter application cannot be improved by using a scale factor greater than 1. 00000. 4. The number of pulses per single unit must be greater than or equal to the DDD value for the scale factor to be less than or equal to one. 5. Lowering the scale factor can be accomplished by lowering the counter decimal position. (Example: 100 (Hundredths)/10 pulses = 10.000 lowering to 10 (Tenths)/10 = 1.000.) COUNTER B RESET POWER-UP Counter B may be programmed to reset at each meter power-up. 8 DIGIT COUNT VALUES Any counter display value below -99999 or above 999999 (less decimal point) will consist of a two part display. This display alternates between the least 6 significant digits and the remaining most significant digits beginning with “” in the display. If the display exceeds ± 99999999 the display will roll to zero and continue counting. Outputs cannot be set to counter values above 6 digits. The annunciator, indicating the counter being displayed, will flash when the value is above 6 digits. PAXI: PRESCALER SCALE VALUE to The prescaler output frequency is the Input A frequency times the prescaler scale value. |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |