| 전자부품 데이터시트 검색엔진 |
|
AMC6821 데이터시트(PDF) 39 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
AMC6821 데이터시트(HTML) 39 Page - Texas Instruments |
|
39 / 57 page ![]() www.ti.com DEVICE STATUS REGISTERS AMC6821 SBAS386C – MAY 2006 – REVISED JULY 2007 Reading the status registers clears the appropriate status bit. Status register bits are sticky (except the RTF bit). Whenever a status bit is set, indicating an out-of-limit condition, it remains set until the event that caused it is resolved and the status register is read. The status bit can only be cleared by reading the status register after the event is resolved. All bits are cleared when reading the register, and all bits are reasserted if the out-of limit condition still exists on the next monitoring cycle, unless otherwise noted. Status Register 1 (Address 0x02, Value After Power-On or Reset = 0x00) BIT NAME R/W DEFAULT DESCRIPTION LTL = 1 when the local temperature is less than or equal to the value of the 7 LTL R 0 Local-Low-Temp-Limit register. Otherwise, LTL = 0. If the local temperature is still outside the local temperature low limit, this bit reasserts on the next monitoring cycle. LTH = 1 when the local temperature is greater than or equal to the value of the 6 LTH R 0 Local-High-Temp-Limit register. Otherwise, LTH = 0. If the local temperature is still outside the local temperature high limit, this bit reasserts on the next monitoring cycle. Remote sensor-failure interrupt. RTF = 1 when the remote temperature sensor fails (short- or open-circuit). RTF = 0 when the remote sensor is in normal condition. When RTF = 1, the OVR pin is asserted and the remote temperature data register is set to –128 °C. 5 RTF R 0 RTF = 1 also generates an interrupt through the SMBALERT pin if an interrupt is enabled (RTFIE = 1). Once RTF is set ('1'), it always remains ('1') until power-on reset or software reset occurs, whether or not the failure condition continues. Reading the status register does not clear the RTF bit. Remote temperature over the remote THERM limit flag. R-THERM = 1 when the temperature is greater than the value of the Remote-THERM-Limit register. Otherwise, R-THERM = 0. When R-THERM = 1, the THERM pin goes low. It also generates a 4 R-THERM R 0 THERM interrupt if THERMOVIE = 1. This bit is cleared on a read of Status Register 1. Once cleared, this bit is not reasserted until the remote temperature falls 5 °C below this THERM limit, even if the THERM condition persists. Refer to the THERM Pin and External Hardware Control section. RTL = 1 when the remote temperature is less than or equal to the value of the 3 RTL R 0 Remote-Low-Temp-Limit register. Otherwise, RTL = 0. If the remote temperature is still beyond the remote temperature low limit, this bit reasserts on the next monitoring cycle. RTH = 1 when the remote temperature is greater than or equal to the value of 2 RTH R 0 Remote-High-Temp-Limit register. Otherwise, RTH = 0. If the remote temperature is still beyond the remote temperature high limit, this bit reasserts on the next monitoring cycle. Fan-slow flag. FANS = 1 if the TACH data are greater than or equal to the value of the TACH-Low-Limit register. This bit indicates if the fan becomes stuck or goes under the minimum speed. FANS = 0 if the TACH data are smaller than the TACH low limit. This bit is cleared ('0') only after reading this register, and reasserts '1' in the next monitoring if a fan-slow is detected. After spin-up, FANS is set ('1') even if the TACH data are less 1 FANS R 0 than the TACH low limit until the register is read. FANS = 1 generates a fan out-of-range interrupt through the SMBALERT pin if fan out-of-range is enabled (FANIE = 1). Five consecutive fan-slow events result in a FAN FAILURE status; which asserts the FAN-FAULT pin low. See the FAN-FAULT PIN section for details. Note that a FANS (fan-slow) detection is not performed during spin-up. RPM-ALARM = 1 when the TACH data are less than or equal to the value of the TACH-High-Limit register. This means the RPM is over the maximum limit defined by the TACH high limit. Otherwise, RPM-ALARM = 0. This bit is cleared when reading this register. Once cleared, this bit is not reasserted on the next monitoring cycle even if the 0 RPM-ALARM R 0 condition still persists. This bit may be reasserted only if the RPM drops below the allowed maximum speed. RPM-ALARM = 1 generates a fan out-of-range interrupt through the SMBALERT pin if fan out-of-range is enabled (FANIE = 1), but does not cause an interrupt through the FAN-FAULT pin. Copyright © 2006–2007, Texas Instruments Incorporated Submit Documentation Feedback 39 Product Folder Link(s): AMC6821 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |