전자부품 데이터시트 검색엔진
  Korean  ▼
ALLDATASHEET.CO.KR

X  

AFE031 데이터시트(PDF) 40 Page - Texas Instruments

부품명 AFE031
상세설명  AFE031 Powerline Communications Analog Front-End
PDF  59 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
제조업체  TI2 [Texas Instruments]
홈페이지  https://www.ti.com
Logo TI2 - Texas Instruments

AFE031 데이터시트(HTML) 40 Page - Texas Instruments

Back Button AFE031 Datasheet HTML 36Page - Texas Instruments AFE031 Datasheet HTML 37Page - Texas Instruments AFE031 Datasheet HTML 38Page - Texas Instruments AFE031 Datasheet HTML 39Page - Texas Instruments AFE031 Datasheet HTML 40Page - Texas Instruments AFE031 Datasheet HTML 41Page - Texas Instruments AFE031 Datasheet HTML 42Page - Texas Instruments AFE031 Datasheet HTML 43Page - Texas Instruments AFE031 Datasheet HTML 44Page - Texas Instruments Next Button
Zoom Inzoom in Zoom Outzoom out
 40 / 59 page
background image
SPI
SPI
LPF
LPF
Line Coupling Interface
C2000 MCU
AFE031
PA
DAC
PGA
PGA
PGA
Copyright © 2017, Texas Instruments Incorporated
Line Coupling Interface
C2000 MCU
SPI
LPF
AFE031
LPF
SPI
PA
DAC
PGA
PGA
PGA
Copyright © 2017, Texas Instruments Incorporated
40
AFE031
SBOS531E – AUGUST 2010 – REVISED JUNE 2019
www.ti.com
Product Folder Links: AFE031
Submit Documentation Feedback
Copyright © 2010–2019, Texas Instruments Incorporated
9.5 Calibration Modes
The AFE031 can be configured for two different calibration modes: Tx calibration and Rx calibration. Calibration
values can be determined during the calibration process and stored in system memory. A one-time calibration
can be performed the first time that the system powers on; this calibration remains valid over the full temperature
range and operating life of the AFE031, independent of the number of power-on/power-off cycles, as long as the
calibration factors remain in the system memory. Calibration mode is accessed through the Control1 Register.
Note that calibration is not required.
9.5.1 Tx Calibration Mode
The Tx PGA + Tx Filter ac gain can be calibrated in Tx calibration mode. Figure 45 shows the signal path during
Tx calibration mode.
Figure 45. Tx Calibration Mode Configuration
9.5.2 Rx Calibration Mode
The Tx PGA + Rx PGA1 + Rx Filter + Rx PGA2 ac gain can be calibrated in Rx Calibration mode. Figure 46
shows the signal path during Rx Calibration mode.
Figure 46. Rx Calibration Mode Configuration



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59


데이터시트 다운로드

Go To PDF Page


링크 URL



ALLDATASHEET 가 귀하에 도움이 되셨나요?  [ DONATE ] 

Alldatasheet는?   |   광고문의   |   운영자에게 연락하기   |   개인정보취급방침   |   링크 투 데이터시트    |   링크교환   |   제조사별 검색
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com