7 / 38 page ![]() 7.6 Insulation Specifications over operating ambient temperature range (unless otherwise noted) PARAMETER TEST CONDITIONS VALUE UNIT GENERAL CLR External clearance(1) Shortest terminal-to-terminal distance through air ≥ 8.5 mm CPG External Creepage(1) Shortest terminal-to-terminal distance across the package surface ≥ 8.5 mm DTI Distance through the insulation Minimum internal gap (internal clearance) of the double isolation (2 x 0.0105 mm) ≥ 0.021 mm CTI Comparative tracking index DIN EN 60112 (VDE 0303-11); IEC 60112 ≥ 600 V Material Group According to IEC 60664-1 I Overvoltage category Rated mains voltage ≤ 600 VRMS I-IV Rated mains voltage ≤ 1000 VRMS I-III DIN VDE 0884-11 (VDE V 0884-11): 2017-01 VIORM Maximum repetitive peak isolation voltage AC voltage (bipolar) 2121 VPK VIOWM Maximum isolation working voltage AC voltage (sine wave); time-dependent dielectric breakdown (TDDB) test; see Figure 4 1500 VRMS DC voltage 2121 VDC VIOTM Maximum transient isolation voltage VTEST = VIOTM, t = 60 s (qualification test) 7071 VPK VTEST = VIOTM, t = 1 s (100% production test) 8485 VPK VIOSM Maximum surge isolation voltage(2) Test method per IEC 60065, 1.2/50 µs waveform, VTEST = 1.6 × VIOSM = 12800 VPK (qualification) 8000 VPK qpd Apparent charge(3) Method a: After I/O safety test subgroup 2/3, Vini = VIOTM, tini = 60 s; Vpd(m) = 1.2 × VIORM = 2545 VPK, tm = 10 s ≤ 5 pC Method a: After environmental tests subgroup 1, Vini = VIOTM, tini = 60 s; Vpd(m) = 1.6 × VIORM = 3394 VPK, tm = 10 s ≤ 5 Method b1: At routine test (100% production) and preconditioning (type test), Vini = VIOTM, tini = 1 s; Vpd(m) = 1.875 × VIORM = 3977 VPK, tm = 1 s ≤ 5 CIO Barrier capacitance, input to output(4) VIO = 0.4 × sin (2 πft), f = 1 MHz ~1.5 pF RIO Insulation resistance, input to output(4) VIO = 500 V, TA = 25°C > 1012 Ω VIO = 500 V, 100°C ≤ TA ≤ 125°C > 1011 VIO = 500 V at TS = 150°C > 109 Pollution degree 2 Climatic category 55/125/21 UL 1577 VISO Withstand isolation voltage VTEST = VISO = 5000 VRMS, t = 60 s (qualification), VTEST = 1.2 × VISO = 6000 VRMS, t = 1 s (100% production) 5000 VRMS (1) Creepage and clearance requirements should be applied according to the specific equipment isolation standards of an application. Careshould be taken to maintain the creepage and clearance distance of a board design to ensure that the mounting pads of the isolator onthe printed-circuit board do not reduce this distance. Creepage and clearance on a printed-circuit board become equal in certain cases.Techniques such as inserting grooves, ribs, or both on a printed-circuit board are used to help increase these specifications. (2) Testing is carried out in air or oil to determine the intrinsic surge immunity of the isolation barrier. (3) Apparent charge is electrical discharge caused by a partial discharge (pd). (4) All pins on each side of the barrier tied together creating a two-pin device. www.ti.com AMC1300 SBAS895D – MAY 2018 – REVISED MAY 2022 Copyright © 2022 Texas Instruments Incorporated Submit Document Feedback 7 Product Folder Links: AMC1300 |
|
링크 URL |
| ALLDATASHEET 가 귀하에 도움이 되셨나요? [ DONATE ] |
Alldatasheet는? | 광고문의 | 운영자에게 연락하기 | 개인정보취급방침 | 링크 투 데이터시트 | 링크교환 | 제조사별 검색 All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |